Care and Cleaning

To clean, wipe down with a damp cloth and towel dry.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.

Troubleshooting

NOTE: Refer to the service parts section in this manual for a
detailed drawing showing the location of the parts listed below.
Problem
There are leaks from the
handle.
The aerator leaks or has a
reduced water flow.
The sink drain at the base of
the sink is leaking.
The water will not shut off
completely.
Possible Cause
The bonnet nut is loose.
The O-ring on the cartridge is
dirty or damaged.
The aerator is dirty or mis-fitted.
The cartridge may be clogged.
The sink surface is rough or
irregular.
The cartridge bonnet nut
is loose or cartridge is not
positioned correctly.
The cartridge is damaged.
Tighten the bonnet nut.
Clean or replace the O-ring.
Remove the aerator and check for
debris.
Remove cartridge and check for
debris.
Ensure the aerator is properly
installed.
Apply additional silicone sealant to
the beveled side of the drain flange.
Apply silicone sealant to the beveled
side of the rubber washer on the
drain body.
Retighten and test for leaks.
Reinstall the cartridge after cleaning
and tighten the bonnet nut.Tighten
lock nut.
If problem still exist, replace the
cartridge.
10