Description Of The Appliance; Characteristics; Check And Safety Devices; Identification - Climit 24 HE Plus Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1

DESCRIPTION OF THE APPLIANCE

1.1

Characteristics

HE Plus
are last generation condensing wall mounted boilers
which Climit has produced for heating and domestic hot water
production. The main design choices made by Climit for the HE
boilers are:
Plus
– the total pre-mix microflame burner combined with a steel
heat exchanger for heating and a rapid heat exchanger for
DHW
– the sealed combustion chamber which can be classified
"Type C" or "Type B" in relation to the room where the boiler
is installed, depending on the smoke outlet configuration
adopted during installation
– the command and control microprocessor electronic board
provides efficient management of both heating and hot water
production. It can also be connected to a remote control
with an Open Therm protocol or to room thermostat and/or
external sensor. If connected to an external sensor, the boiler
temperature varies on the basis of the external temperature
according to a selected optimal climatic curve providing
significant energy and economic savings.
Other special features of the HE Plus boilers are:
– the anti-freeze function which activates automatically if the
temperature of the water inside the boiler falls below the
threshold of the value set at parameter "PAR 10" and , if there
is an external sensor, if the external temperature falls below
the threshold of the value set at parameter "PAR 11"
– the anti-blocking function of the pump and diverter valve, this
activates automatically every 24 hours if no request for heat
has been made
– the chimney sweep function lasts 15 minutes and makes the
job of the qualified technician easier when measuring the
parameters and combustion efficiency
– domestic hot water comfort function which allows the time
necessary for the hot water to become available to be reduced
and ensures that the temperature is stable
– screen display of the operating and self-diagnostic
parameters with error code display when the fault occurs.
This makes repair interventions easier and allows appliance
operation to be restored correctly.
1.2

Check and safety devices

The HE Plus boilers are equipped with the following check and
safety devices:
– thermal safety thermostat 100°C
– 3 bar relief valve
– heating water pressure transducer
– delivery sensor
– DHW sensor
– smoke flue gas probe.
d
IT IS FORBIDDEN
to commission the appliance with safety devices which
do not work or which have been tampered with.
a
WARNING
Safety device may only be replaced by professional
qualified personnel using Climit original spare parts.
102
1.3

Identification

The HE Plus boilers can be identified by means of:
this is located on the outside of the
1
Packaging label:
packaging and provides a code, the serial number of the
boiler and the bar code
this is positioned on the outside
2
Energy Efficiency Label:
of the packaging to notify the User of the level of energy
savings and reduced environmental pollution produced by
the appliance
this is located inside the front panel of
3
Technical Data Plate:
the boiler and provides the technical specification, appliance
performance and any other information required by law.
1
811....
CLIMIT
811....
2
I
II
A
++
A
A
+
B
A
C
B
D
C
D
E
E
F
F
G
G
kW
dB
2015
811/2013
Cod. 6244745
3
EN
1
2
3
Fig. 1

Publicidad

Tabla de contenido
loading

Tabla de contenido