2.13.1 External Sensor; 2.13.2 Chrono-Thermostat Or Air Thermostat; Example Of Use Of The Command/Control Device On Some Types Of Heating Systems - Climit 24 HE Plus Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
d
IT IS FORBIDDEN
To use water pipes for earthing the appliance.

2.13.1 External sensor

The boiler is prearranged for connection to an external air
temperature sensor and can operate with a sliding temperature.
This means that the delivery temperature sent to the boiler can
vary on the basis of the external temperature depending on the
climatic curve selected from those shown in the diagram (Fig.
22).
When fitting the sensor on the outside of the building, follow
the instructions provided on the packaging of the product itself.
Climatic curve
Delivery temperature
°C
90
K=9
K=8
80
70
60
50
40
30
20
20
15
10
5
m
CAUTION
If there is an external sensor, in order to select the
optimal climatic curve for the system and therefore
the delivery temperature based on the external
temperature:
– press the button
t
– press buttons
>
or
been selected (within the range K=0.0 - K=9.0 ).

2.13.2 Chrono-thermostat or Air Thermostat

The electrical connection of the chrono-thermostat or air
thermostat has already been described. When fitting the
component in the room where the readings are to be taken,
follow the instructions provided on the packaging of the product
itself.
2.13.3 EXAMPLE of use of the command/control
device on some types of heating systems
KEY
M
System delivery
R
System return
CR
Remote control
SE
External sensor
TA
Air thermostat for boiler activation
TZ1÷TZ3 Air thermostat for the zone
VZ1-VZ3 Zone valves
RL1-RL3 Zone relays
P1-P3
Zone pump
TSB
Low temperature safety thermostat
K=7
K=6
K=5
K=4
K=3
K=2
K=1
°C
0
-5
-10
-15
-20
External temperature
Fig. 22
for 1 second
<
until the required curve K has
ONE DIRECT ZONE system , external sensor and air thermostat.
SE
M
R
CR
TA
MULTI ZONE system - with pump, air thermostat and external
sensor.
TZ1
TA
RL1
SE
M
R
P1
SP
MULTI ZONE system - with zone valve, air thermostat and
external sensor.
TA
TZ1
SE
M
R
VZ1
m
CAUTION
Set the parameter "tS 17 = DELAY SYSTEM PUMP
ACTIVATION to allow the opening of zone valve Vz.
Fig. 23
TZ2
TZ3
RL2
RL3
P2
P3
Fig. 24
TZ2
TZ3
VZ2
VZ3
Fig. 25
117

Publicidad

Tabla de contenido
loading

Tabla de contenido