Using Lithium Charge Modes.
Lithium charge modes are designed for 6-volt, 12-volt and 24-volt lithium iron phosphate (LiFePO4).
CAUTION. USE THIS MODE WITH EXTREME CARE. THIS MODE SHOULD ONLY BE USED WITH 6-VOLT, 12-VOLT AND 24-VOLT LITHIUM BATTERIES
THAT HAVE A BUILT-IN BATTERY MANAGEMENT SYSTEM (BMS). LITHIUM-ION BATTERIES ARE MADE AND CONSTRUCTED IN DIFFERENT WAYS
AND SOME MAY OR MAY NOT CONTAIN A BATTERY MANAGEMENT SYSTEM (BMS). CONSULT THE LITHIUM BATTERY MANUFACTURER BEFORE
CHARGING AND ASK FOR RECOMMENDED CHARGING RATES AND VOLTAGES. SOME LITHIUM-ION BATTERIES MAY BE UNSTABLE AND UNSUITABLE
FOR CHARGING.
Using Supply Modes. [Press and Hold 3 Seconds While Not Connected To Battery]
Supply Mode converts the charger to a constant voltage DC power supply. It can be used to power 12VDC and devices, tire inflators, seat heaters and
more. As a power supply, it can also be used to retain a vehicle's on-board computer settings during battery repair or replacement.
13.6V Supply (12V Supply) provides 13.6-volts up to 25A. Charger output voltage will drop if output load exceeds the 25A current limit.
27.2V Supply (24V Supply) provides 27.2-volts up to 12.5A. Charger output voltage will drop if output load exceeds the 12.5A current limit.
CAUTION. USE THIS MODE WITH EXTREME CARE. SUPPLY MODE DISABLES SAFETY FEATURES AND LIVE POWER IS PRESENT AT THE
CONNECTORS. DO NOT TOUCH CONNECTIONS TOGETHER. RISK OF SPARKS, FIRE, EXPLOSION, PROPERTY DAMAGE, INJURY, AND DEATH.
Using Repair Modes. [From Standby Press and Hold 3 Seconds While Connected to the Battery]
Repair is an advanced battery recovery mode for repairing and storing, old, idle, damaged, stratified or sulfated batteries. Not all batteries can be
recovered. Batteries tend to become damaged if kept at a low charge and/or never given the opportunity to receive a full charge. The most common battery
problems are battery sulfation and stratification. Both battery sulfation and stratification will artificially raise the open circuit voltage of the battery, causing
the battery to appear fully charged, while providing low capacity. Use Repair in attempt to reverse these problems. For optimal results, take the battery
through a full charge cycle, bringing the battery to full charge, before using this mode. Repair Mode can take up to four (4) hours to complete the recovery
process and will return to Standby when completed. Repeated repair cycles may be needed depending on size and condition of the battery, however battery
temperature must be closely monitored.
CAUTION. USE THIS MODE WITH CARE. THIS MODE IS FOR 6-VOLT, 12-VOLT AND 24-VOLT LEAD-ACID BATTERIES ONLY. THIS MODE USES A HIGH
CHARGING VOLTAGE AND MAY CAUSE SOME WATER LOSS IN WET (FLOODED) CELL BATTERIES. BE ADVISED, SOME BATTERIES AND ELECTRONICS
MAY BE SENSITIVE TO HIGH CHARGING VOLTAGES. TO MINIMIZE RISKS TO ELECTRONICS, DISCONNECT THE BATTERY BEFORE USING THIS MODE.