SATA 03055 Manual Del Uso página 46

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 191
03055 /03075
the circuit.
5. Take the readings. During DC measurement, the polarity of connecting end of the red probe will be indicated.
- Measuring resistance
1. Connect the black probe to "COM" jack and the red probe to "
2. Set the function switch to "
3. Connect the test probes to both ends of the resistor to be measured.
4. Take readings.
Note
1. It may take several seconds to obtain a stable reading when the resistance is greater than 1MΩ, which is normal for measurement of
high resistance.
2. When the input terminal is open circuited, "OL" will appear on the screen to indicate overrange.
3. Before measurement, please switch off the power of the measured circuit and fully discharge all capacitors.
- Continuity test
1. Connect the black probe to "COM" jack and the red probe to "
2. Set the function switch to "
3. Connect the test probes to both ends of the circuit to be measured.
46
" position, and then press and hold "SELECT" button until "
" position, and then press and hold "SELECT" button until "
" jack.
" and"
" jack.
"symbol appears on the screen.
EN
DE
RU
KO
PT
" symbols disappear off the screen.
JA
ES

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

03057

Tabla de contenido