Electrical Connections - DITEC E1T Manual De Instalación

Cuadro electrónico para automatismos 400 v trifásicos de 1 motor
Ocultar thumbs Ver también para E1T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
1.

ELECTRICAL CONNECTIONS

GB
1.1 Commands
Command
1
2
1
3
1
4
41
6
41
8
1
9
1
9
1
20
0
11
0
12
17
WARNING: Make a jumper on all NC contacts if not in use. The terminals with the same number are equal. The given operating
and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
1.2 Self-controlled safety edge SOFA1-SOFA2
Command
1
6
N.C.
1
8
N.C.
41
E1T - IP1897
Function
N.O.
AUTOMATIC CLOSING
N.O.
OPENING
STEP-BY-STEP
N.O.
CLOSING
N.C.
SAFETY STOP
N.C.
REVERSAL SAFETY DEVICE Opening the safety contact triggers a reversal of the movement
N.C.
STOP
EMERGENCY STOP
N.O.
HOLD TO RUN FUNCTION
PARTIAL OPENING
N.C.
CLOSURE LIMIT SWITCH
N.C.
OPENING LIMIT SWITCH
Function
SAFETY STOP
REVERSAL SAFETY DEVICE Connect the output contact of device SOFA1-SOFA2 to terminals 1-8
SAFETY TEST
Permanently closing the contact enables automatic closing.
With DIP1=ON the closure of the contact activates an opening ope-
ration.
With DIP1=OFF the closure of the contact activates an opening or
closing operation in the following sequence: open-stop-close-open.
Note: if automatic closing is enabled, the stop is not permanent but
at a time that is set by the TC.
The closing manoeuvre starts when the contact is closed.
All operations are stopped and/or blocked when the contact is opened.
(reopening) during a closing operation.
Opening the safety contact stops the current operation.
To enable the emergency stop function (e.g. with a specific red but-
ton), connect the opening and closing controls to terminal 9 instead
of 1 (9-3, 9-4, 9-20).
Permanently opening the safety contact enables the operator pre-
sence dependent function.
In this state, the opening (1-3/1-20) and closing (1-4) controls fun-
ction only if held in the pressed position, and the automation stops
when the controls are released.
All safety switches, the step-by-step control and the automatic clo-
sing function are disabled.
The closing of the contact activates a partial opening operation of
the duration set with the RP trimmer.
Once the automation stops, the partial opening control performs
the opposite operation to the one performed before stoppage.
The opening of the limit switch contact stops the closure operation.
The opening of the limit switch contact stops the opening operation.
FUTURE USE
Connect the output contact of device SOFA1-SOFA2 to terminals 1-6
on the control panel (in series with the photocell output contact, if
installed).
on the control panel (in series with the photocell output contact, if
installed).
Connect the terminal of device SOFA1-SOFA2 to terminal 41 of the
control panel. Connecting terminal 41 enables a safety edge test cycle
before every operation. If the test fails the SA led flashes and the test
is repeated.
10
Description
Description

Publicidad

Tabla de contenido
loading

Tabla de contenido