DITEC E1T Manual De Instalación página 11

Cuadro electrónico para automatismos 400 v trifásicos de 1 motor
Ocultar thumbs Ver también para E1T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
1.3 Outputs and accessories
Output
1
+
24 V= / 0,5 A
0
-
1
11
1
12
24V= / 50 W
0
14
-LK+
U
W
V
M
400 V~ / 6 A
3~
ON
2.
SETTINGS
2.1 Trimmer
Trimmer
Setting automatic closing time. From 0 to 120 s.
TC
Note: after the activation of the stop command, once contact 1-9 has closed again, the automatic clo-
MIN=0 s
MAX=120 s
sing is only activated after a total, partial or step-by-step opening command.
Motor partial opening adjustment. From 0 to 30 s.
RP
0 s
30 s
Value
Accessories power supply. Power supply output for external accessories, inclu-
ding automation status lamp.
24 V= / 3 W
Automation open lamp. The light switch off when the automation is closed.
(0,125 A)
24 V= / 3 W
Automation closed lamp. The light switches off when the automation is open.
(0,125 A)
Flashing light (LAMPH). Activated during opening and closing operations.
(2 A)
DO NOT USE
Three-phase motor.
Connect the contact of the motor circuit breaker in series to the limit switch.
Note: if the direction of rotation of the motor is incorrect for the desired direction
of movement, swap the L2 and L3 phases.
Membrane push-button panel (PT3). Starts the opening operation.
N.B.: connect the push-button panel connector to J7 as indicated in fig. 6.1.
Connect the push-button panel to J7 rotated through 180° to activate the closing
operation.
Membrane push-button panel (PT3). Causes the blocking of the movement.
Membrane push-button panel (PT3). Starts the closing operation.
Note: connect the push-button panel connector to J7 as indicated in fig. 6.1.
Connect the push-button panel to J7 rotated through 180° to activate the opening
operation.
Membrane push-button panel (PT4). Starts the opening operation.
Note: the green LED on indicates the presence of the 24 V=power supply.
Membrane push-button panel (PT4). Starts the partial opening operation.
Membrane push-button panel (PT4). Starts and stops the STOP operation.
Note: the red LED on indicates that the STOP has been activated. the flashing red
LED indicates that the safety devices have been activated.
Membrane push-button panel (PT4). Starts the closing operation.
Description
Description
11
GB
E1T - IP1897

Publicidad

Tabla de contenido
loading

Tabla de contenido