(USE ONLY FOR THE ELEMENTS TO). Once this fire ignition control its intensity through the
records to get the desired combustion (2.2.). When the fuel load has been reduced should
return to recharge taking into account the specified data above.
2.7. Mechanism blockage. It is compulsory to check any piece because they might get stuck
after a long period of time without using the fireplace. Keep outdoor inlet free from blockage.
2.8. Load opening.
2.8.1. Guillotine opening: in this system, the door move from down to upwards and it is useful
for loading.
2.8.2. Swing opening
This function is used for the cleaning or changing glass, seals etc. To
(30)
open the doors, use specific tool, rocking it on the upper frame and pulling to the left so the door
moves down.
2.9. Cleaning and maintenance.
2.9.1. Glass cleaning. To clean the glass, the apparatus must not be operating. Do not clean
with any liquid either the metal parts of the door or the seal, in order to prevent damage.
2.9.2. Ash box cleaning. Empty the ash box when the apparatus is totally off. Watch out hot
ash. When doing it, dump the ash into a metal bucket.
2.9.3. Smokestack cleaning. It is necessary to clean the chimney at least once a year. The
only thing to be done is to remove the deflexed panel.
2.9.4. Paint. The exothermic paint that covers the inside and the outside of the apparatus can
bear up to 600ºC. Previously it has been in drying oven, but the process of polymerization will
be reached with the first fires, so a peculiar odour will spread out. It is also possible that after
some time, the paint inside the fireplace wears off due to the liquid corrosion, fuel or other
reasons. In this case, it will be necessary to wear the rusty zones off and repaint them again.
2.10. Fire Prevention. No flammable element must be placed the nearest at 1000 mm away
from the fireplace. Special prevention must be taken when children or elderly around.
In case of a fire, move away all people around, close registers and call the Firemen Department.
2.11.Operating the fireplace under certain weather conditions. It is possible that under
certain weather conditions the apparatus doesn't work properly: smoke mislead or not enough
intake. When observing these phenomena, it is highly recommended to close all air registers
and extinguish the fire.
2.12. Fireplace modification. Any modification must be authorized by means of writing on
behalf of Manufacturas Rocal SA. It is also compulsory to use the spare pieces recommended
by Manufacturas Rocal SA.