PREPARE THE HOOD
NON - DUCTED CONFIGURATION ONLY
7. Carefully place the lower flue into the re-
cessed area of the range hood.
8. Carefully slide the upper flue down inside
the lower flue.
9. Secure the recirculation plenum to the up-
per flue with (4) flat head screws.
WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical
codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Feed 6" of power cable through the knock-
out opening and secure cable to the wir-
ing box with an appropriate connector.
3. Make electrical connections. Connect
white to white, black to black and green
to green.
4. Replace wiring box cover and screws.
Make sure that wires are not pinched be-
tween cover and box.