PREPARE THE HOOD
NON - DUCTED CONFIGURATION ONLY
Note: On stainless steel hoods, carefully remove the plastic protective film
from all exterior surfaces of the hood and decorative flues, prior to final installa-
tion.
Note: The following material must be purchased separately for non-ducted re-
circulation installations.
•
Non-Ducted Recirculation Plenum Part Number SB08089123
•
6" diameter expandable / flexible aluminum duct
•
1/16" diameter twist drill
•
Recirculating filter model FILTERK3490CM (for 90 cm wide hoods) or
FILTERK3448 (for 48" wide hoods).
Caution: Use flexible metal duct. Do not use plastic or rigid metal ducting.
1. Determine length of the compressed flexible metal duct using the following
formula:
Distance above
35" MINUS
cook top.
Worksheet: 39" - __________ + __________ (for 9" ceiling only) = __________
2. Remove and discard the damper flaps from
inside the hood's duct connector.
3. Attach 6" round metal flexible duct to the
hoods 6" duct connector. Tape all joints with
duct tape.
4. Assemble the recirculation plenum to the
flexible duct.
5. Drill three 1/16" diameter equally spaced
holes though the duct and duct connector
on the recirculation plenum.
6. Secure the duct to the plenum's connector
with (3) sheet metal screws. Tape all joints
with aluminum duct tape.
12" if ceiling height
PLUS
is 9-feet
CONNECTOR
- 9 -
Compressed
=
length of flexible
aluminium
ductwork
PLENUM
(3) SCREWS
6" ROUND
METAL
FLEXIBLE
DUCT
DUCT