INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS
The following is intended to provide the basic instructions for installation, operating and maintenance of the FireFox .
Tools required
• Utility knife
• Medium Phillips screwdriver
• Small Phillips screwdriver
• Electrician's pliers (multipurpose, stripping and crimping)
PRODUCT RATINGS
Maximum motor current draw:
12 volt versions 15 . 0 amps each for elevation and rotation motors
24 volt versions 7 . 5 amps each for elevation and rotation motors
Normal operating current (depending on operating conditions - pressure, flow, etc.):
12 volt versions 3 - 10 amps each for elevation and rotation motors
0 . 7 amps for nozzle pattern motor
24 volt versions 2 - 5 amps each for elevation and rotation motors
0 . 4 amps for nozzle pattern motor
Minimum Voltage: (Truck engine must be operating for proper voltage requirement.)
All 12 volt motors: 11.5 volts while operating
All 24 volt motors: 23 volts while operating
Mass: 31 lbs. (17.7 kg)
Maximum Flow: 500 GPM (1420 lpm)
Maximum Pressure: 200 PSI (14 bar)
Noise Emission: 91 Db @1m with maximum flow
PRODUCT WARNINGS
WARNING: The maximum flow of the FireFox is 500 GPM. The center of the waterway outlet is 10.75 inches from
!
the bottom of the inlet. Ensure these values and an appropriate safety factor is used to determine a
proper support structure .
WARNING:
Aim the FireFox in a safe direction before pumping water through it .
!
WARNING:
Although the logic box includes a water resistant coating it is important to keep water out of the control
!
and logic boxes. Prolonged exposure to water will cause damage. When the cover of the control or logic
box is removed check that the O-Ring under the cover is intact and free of dirt and debris.
WARNING:
The FireFox uses current limiting for both the monitor and nozzle stops. Use only appropriate Akron
!
Brass nozzles .
WARNING:
Do not use the electric controls when the override cranks are being used or are in position for use.
!
WARNING:
If any tags or bands are worn or damaged and cannot be easily read, they should be replaced.
!
WARNING:
Disconnect power and disable flow before maintenance .
!
WARNING:
Keep all personnel out of the Danger Zone (Figure 4), in front of the outlet of the monitor when the water
!
source is attached. Dangerous flow velocities can cause serious injury.
STYLE 3463 FIREFOX™ FOR UII CONTROL
• Medium flat screwdriver
• Small flat screwdriver
• 1/2 inch hex head wrench
3 . 0 amps for nozzle pattern motor
1 . 5 amps for nozzle pattern motor
122446