Datamars Unigizer 15 J Guía De Instalación Y Uso página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Testing the battery voltage
The energizer's Battery Test setting can be used to monitor the battery voltage.
When the selector switch is set to Battery Test , the Indicator lights show the input supply voltage. This can be useful in order to
monitor the battery charge level.
Note:
When the selector switch is set to Battery Test , the energizer pulses at slow speed (2.5 seconds between pulses) and the
fence is live.
Lights
or
Notes:
- In extreme temperatures, these guidelines may not apply.
- The battery test results will display for 30 seconds after the selector switch is set to Battery Test .
When the selector switch is set to Battery Test , the LCD display also displays the input supply
When the voltage is outside the normal range (below 11.8 V or above 17 V), the battery symbol
flashes.
During normal operation, when the selector switch is set to
the LCD display flashes. Recharge the battery immediately.
10
Input supply
voltage
Battery-only installation
Above 17.0 V
Abnormal conditions, check battery and connections.
12.6 V-17.0 V
Full battery charge voltage (80-100%):
• No action required.
12.3-12.6 V
Medium battery charge voltage (50-80%):
• No action required.
12.0-12.3 V
11.7-12.0 V
Low battery charge voltage (20-50%):
• Monitor battery voltage.
• Recharge the battery to avoid long-term damage to the battery.
11.2-11.7 V
Bad battery charge voltage (10-20%):
• Recharge the battery immediately.
• Energizer will automatically revert to Slow Speed and Low Output Power in order to
preserve the remaining power and energy in the battery.
Below 11.2 V
Very bad battery charge voltage:
• Recharge the battery immediately
• The energizer will not function in order to preserve the battery.
,
,
or
, if the battery voltage is bad, the battery symbol on
voltage.