PART #4-146 REV. 9 12/03
FLUIDMASTER
®
400A FILL VALVE
INSTALLATION INSTRUCTIONS
TOOLS NEEDED:
DO NOT USE:
1.
2.
SHANK AND
CONE WASHER
(SEE STEP 4)
LOCK NUT
CONE
WASHER
COUPLING
ANGLE
NUT
ADAPTER
3.
4.
DO NOT use
PUSH
plumber's putty
DOWN
to seal these
fittings.
These parts must be
used as illustrated to
insure water-tight
HAND
connection. Use of
TIGHTEN
existing coupling nut
ONLY
or cone washer may
result in water leakage.
7.
Water supply tube or pipe must extend at least
1/2" inside threaded shank of valve (does not
apply to flanged tubing).
8.
7
9.
10.
REFILL TUBE
7
NOTE: Flow from refill tube must be
positioned just above the overflow
pipe.
11.
LIFT
ARM
FIRST
12.
13.
NOTE: SAVE INSTRUCTION SHEET FOR FUTURE REFERENCE.
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
OVERFLOW
FILL VALVE
®
CONE WASHER
COUPLING NUT
Diagram 1
SHANK
WASHER
"C.L."
MARK
SHANK
SHANK
WASHER
TANK
BOTTOM
THREADED SHANK
5.
METAL/COPPER
METAL FLANGED
FLARED TUBING
TUBING
LOCK
NUT
CONE
WASHER
COUPLING
NUT
WATER
SHUT-OFF
Use existing
coupling nut
and washer.
CAUTION: DO NOT USE CONE WASHER
WITH PLASTIC SUPPLY LINE.
®
ANGLE
ADAPTER
Do not insert refill tube down into over-
OVERFLOW
NIPPLE
PIPE
flow pipe below water level. This will
siphon water down the overflow pipe,
which causes the valve to turn on and
off as it tries to keep the tank full.
14.
ARM
TOP
NIPPLE
REFILL
TUBE
ANGLE
ADAPTER
1" ABOVE
FLOAT CUP
TANK
PIPE
LEVER
OVERFLOW
PIPE
LINK
FLUSH
VALVE
VALVE
BODY
WATER LEVEL
ADJUSTMENT
CLIP
ADJUSTABLE
HEIGHT
SHANK
WASHER
FLAPPER
THREADED
SHANK
LOCK NUT
PARTS FOR WATER
CONNECTION
(SEE STEP 8)
MEASURE
HEIGHT ONLY: DO
NOT INSTALL
1"
6.
METAL SPIRAL
VINYL/BRAIDED
TUBING
CONNECTOR
LOCK
LOCK
LOCK
NUT
NUT
NUT
EXISTING
EXISTING
COUPLING
CONE
WASHER
NUT
WASHER
EXISTING
COUPLING
COUPLING
NUT
NUT
WATER
WATER
WATER
SHUT-OFF
SHUT-OFF
SHUT-OFF
Use existing spiral cone washer.
Captive cone washers
Fluidmaster cone washer may not seal
already included. No
completely on spiral type supply line.
additional washers
needed.
CAUTION: Overtightening of LOCK NUT or COUPLING
NUT could result in breakage and potential flooding.
Tilt/Flush Valve
Overflows
China Overflows
599
CLAMP
If the angle adapter cannot be used,
you may need the Model 599 Refill
Clamp (not included).
15.
WARNING
DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS
CONTAINING BLEACH OR CHLORINE. Use of such products will:
MUST BE
ABOVE
(1) RESULT IN DAMAGE to tank components and MAY CAUSE
OVERFLOW
FLOODING and PROPERTY DAMAGE and (2) VOID
PIPE
FLUIDMASTER WARRANTY. DO NOT overtighten nuts or
tank/bowl may crack.
Fluidmaster Flush 'n' Sparkle™ Toilet Bowl Cleaning System is recommended for those
choosing to use in-tank bowl cleaners and WILL NOT VOID the FLUIDMASTER
WARRANTY because it will not damage tank components.
WATER
LEVEL
Because drop-in cleaners used in the tank can result in damaged tank
parts (see WARNING above), Fluidmaster recommends the use of
Flush 'n' Sparkle™ Toilet Bowl Cleaning System (Models 8100, 8200
or 8300). It cleans the bowl without harming tank parts by isolating
the cleaner from the tank water, releasing it only to the bowl where
it is needed. Cartridges supply more than 1,000 flushes and are
a snap to replace.
INSTALLATION WITH FLUIDMASTER
8100 BOWL CLEANING SYSTEM
"IN"
®
"OUT"
Diagram 2
1. Shut off water supply to tank. Flush tank and sponge out remaining
water. Remove old fill valve assembly, using pliers if necessary.
DO NOT
2. If you have a Fluidmaster bowl cleaning system, carefully disconnect
MOVE
the tube from the fill valve. Do not disconnect the tube from the
LOCK RING
dispenser (if you don't have a cleaning system, continue to Step 3).
3. Disassemble small parts – LOCK NUT, SHANK WASHER and ANGLE
ADAPTER for Valve installation (required); CONE WASHER and
COUPLING NUT for Water Supply Connection (optional–see Step 8).
4. Carefully remove CONE WASHER from center of SHANK WASHER.
Place SHANK WASHER on threaded shank of new VALVE. Place flat
surface against valve.
5. When installed, the critical level mark on the fill valve (identified by
a C.L. mark on the Fluidmaster Fill Valve) should be at least 1"
above the top of the overflow pipe. This is a plumbing code.
6. To adjust the height of the fill valve, twist the threaded shank in or out
of valve body. The height of the valve adjusts from 9 to 14 inches. On
some models, a clicking noise will be heard when adjusting the height.
This is normal.
7. Position valve inside tank. Push down on the valve shank (not the top)
while tightening lock nut. Hand tighten only. DO NOT OVERTIGHTEN or
tank may crack. Make sure float cup does not touch toilet tank walls,
trip mechanism or flush valve.
8. Before continuing, determine the type of water supply connection you
have from the chart on the left and use the appropriate assembly parts
required to properly reconnect the water supply. DO NOT use plumber's
putty to seal these fittings.
9. With correct washers in place (see Step 8), tighten coupling nut. Hand
tighten only. DO NOT OVERTIGHTEN. CAUTION: DO NOT USE CONE
WASHER WITH PLASTIC SUPPLY LINE.
10. If you have a Fluidmaster bowl cleaning system, re-attach tube ("IN")
to fill valve nipple (see Diagram 2). Be sure toilet tank flushing compo-
nents move freely (if you don't have a cleaning system, continue to
Step 11).
11. Remove and discard overflow pipe cap if present. Attach one end of
black refill tube to angle adapter and the other end to nipple located
near top of valve. Attach angle adapter to overflow pipe. Trim refill tube
as necessary to prevent kinking. NOTE: Flow from refill tube must be
positioned just above the overflow pipe. Do not insert refill tube down
into overflow pipe below water level. This will siphon water down the
overflow pipe, which causes the valve to turn on and off as it tries to
keep the tank full. If the angle adapter cannot be used, you may need
the Model 599 Refill Clamp (not included).
12. IMPORTANT: Always clear sand and rust from system. Make sure
water supply is shut off. Remove valve TOP by lifting arm and rotating
top and arm 1/8 turn counterclockwise, pressing down slightly on cap.
13. While holding a container over the uncapped VALVE to prevent
splashing, turn water supply on and off a few times. Leave water
supply off.
Built-In
14. Replace TOP by engaging lugs and rotating 1/8 turn clockwise. MAKE
CERTAIN TOP IS TURNED TO THE LOCKED POSITION. VALVE MAY
NOT TURN ON IF TOP IS NOT FULLY TO THE LOCKED POSITION.
15. Turn on water supply. Adjust water to desired level by squeezing water
level adjustment clip and moving FLOAT CUP up or down along stain-
less steel link. Check for leaks, then check for proper flush.
TROUBLESHOOTING
IF FILL VALVE WON'T TURN OFF,
• There may be debris at seal – repeat Steps 12-15.
• The seal inside the valve top may be damaged –replace with genuine
Fluidmaster 242 seal.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE,
• There may be a leak at the flapper.
• The tank ball or flapper is misaligned – repeat Step 11.
Go to our website at www.fluidmaster.com for more
solutions to toilet problems.
GUARANTEE: This Fluidmaster product is guaranteed to be free from defective
materials and workmanship for a period of one year. Units returned to
Fluidmaster, U.S.A., will be replaced without charge.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster
products. Fluidmaster shall not be responsible or liable for any damages
caused by products used in Fluidmaster valves that were not manufactured
by Fluidmaster, Inc.
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675 U.S.A.
(949) 728-2000 (800) 631-2011 www.fluidmaster.com
®
Fights stains
WITHOUT
harming
tank parts.
CLEANING
POWER
More than 1,000 bleaching
flushes in every cartridge.
A crystal
clear bowl
after every
YEAR
flush.
W A R R A N T Y
MADE
Powerful
IN THE
®
USA
bleach injects
ONLY to
KEEP OUT OF REACH
the bowl.
OF CHILDREN
DANGER:
Unlike other
See back panel for additional
precautionary statements
in-tank
cleaners,
MANTENGA LEJOS DEL
ALCANCE DE LOS NIÑOS
WON'T
PELIGROSO:
corrode
Para otros medidas
de precaución, vea el
tank parts.
panel trasero.
Contents: 1 Dispenser & Mounting Bracket, 1 Cartridge, 2 Flexible Tubes, 1 Clip.
Cartridge content net wt. 1.20 oz (34.0 g)
®

Publicidad

loading

Resumen de contenidos para Fluidmaster 400A

  • Página 1 THREADED SHANK 5. When installed, the critical level mark on the fill valve (identified by a C.L. mark on the Fluidmaster Fill Valve) should be at least 1" above the top of the overflow pipe. This is a plumbing code.
  • Página 2 PRECAUCION: NO UTILICE UNA ARANDELA CONICA DE ACOPLAMIENTO, esto podría causar su rotura y ser causa 10. Si tiene el sistema limpiador de taza de Fluidmaster, fije el tubo (“IN”) a la CON UNA LINEA DE SUMINISTRO DE PLASTICO. potencial de desbordamientos de agua.