PART# 4-757, Grev. 5, 10/13
FLUIDMASTER
®
FILL VALVE & FLAPPER
INSTALLATION INSTRUCTIONS
WARNING
DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS CONTAINING BLEACH OR
CHLORINE. Use of such products will: (1) RESULT IN DAMAGE to tank components and MAY
CAUSE FLOODING and PROPERTY DAMAGE and (2) VOID FLUIDMASTER WARRANTY.
Fluidmaster Flush 'n Sparkle Toilet Bowl Cleaning System is recommended for those
choosing to use in-tank bowl cleaners and WILL NOT VOID the FLUIDMASTER WARRANTY
because it will not damage the components. DO NOT overtighten nuts or tank/bowl may crack. Always use quality
Fluidmaster parts when installing or repairing. Fluidmaster will not be responsible or liable for use of non-Fluidmaster parts
during installation or repair.
LIMITED FIVE-YEAR EXPRESS WARRANTY
Subject to the "Exclusions" set forth below, Fluidmaster Inc. promises to the consumer to repair, or at the option of Fluidmaster Inc. to replace any
part of this plumbing product which proves to be defective in workmanship or materials under normal use for five years from the date of purchase. All
costs of removal, transportation and reinstallation to obtain warranty service shall be paid by the consumer. During this "Limited Five Year Express
Warranty," Fluidmaster Inc. will provide, subject to the "Exclusions" section set forth below, all replacement parts free of charge, necessary to correct
such defects. This "Limited Five Year Warranty" is null and void if this plumbing product has not been installed and maintained in accordance with all
written instructions accompanying the product, and if non-Fluidmaster Inc. parts are used in installation.
EXCLUSIONS: FLUIDMASTER INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING COSTS OF INSTALLATION, WATER
DAMAGE, PERSONAL INJURY OR FOR ANY DAMAGES RESULTING FROM ABUSE OR MISUSE OF THE PRODUCT, FROM OVERTIGHTENING OR FROM FAILURE
TO INSTALL OR MAINTAIN THIS PLUMBING PRODUCT IN ACCORDANCE WITH THE WRITTEN INSTRUCTIONS, INCLUDING USE OF NON-FLUIDMASTER PARTS.
DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS CONTAINING BLEACH OR CHLORINE. USE OF SUCH PRODUCTS WILL RESULT IN DAMAGE TO TANK
COMPONENTS AND MAY CAUSE FLOODING AND PROPERTY DAMAGE. USE OF SUCH PRODUCTS WILL VOID THIS WARRANTY.
Preparing the Fill Valve for Installation
2
Fill Valve Assembly Parts
A) Refill Clip
B) Refill Tube
C) Shank Washer
D) Locknut
E) Threaded Shank
A
B
C
Shank Washer
D D
Threaded Shank
Installing New Flapper
4
Put flapper on seat and push down on flapper clips at the
horizontal posts of overflow pipe.
Attach chain clip to tank lever directly above flapper. Leave 1/2" of slack
in chain.
HORIZONTAL
FLAPPER CLIPS
POSTS
SEAT
CHAIN
CLIP
IF FILL VALVE DOES NOT TURN ON, WILL NOT
TURN OFF, OR WILL NOT REFILL THE TANK
AFTER THE FLUSH
• Remove top cap and check for debris. If you find debris, or flow
is weak: Inspect lower section of fill valve for partial blockage.
Partial blockage may be at shut off valve or in water supply line
(See "REMOVING THE VALVE CAP ASSEMBLY & FLUSHING OUT
DEBRIS").
• If fill valve has been in use for some time and/or float cup does not
drop when flushing tank, replace seal with a genuine Fluidmaster 242
seal (See "IF REPLACING SEAL").
– Please keep a copy of these instructions on the property in which the product was installed.
DO NOT USE
SHANK
WASHER
Position fill valve in tank, but do not fully install yet. Top
MEASURE
of fill valve MUST be set 3" above overflow pipe. This will
HEIGHT ONLY:
DO NOT INSTALL
automatically place CRITICAL LEVEL MARK / C.L. Mark, 1"
Place Shank
above the top of overflow pipe. Remove fill valve from tank to
1
"
"C.L"
washer onto
adjust height.
MARK
threaded
Adjust height of fill valve by holding lower shank with right hand
LOCK
shank of fill
RING
and top of valve with left hand. Twist the lower shank counter
valve. Flat
clockwise to increase valve height and clockwise to decrease
side up.
valve height. You should hear several "clicks". Place valve in tank
and check height again. THE CRITICAL LEVEL MARK, identified
by C.L. on valve, MUST be positioned 1" above top of overflow
E
pipe. This is a requirement of the Universal Plumbing Code.
Do not move lock ring. It holds the valve body and shank
together under pressure. Do not interchange body with old shank
as leaking can occur.
Attach Water Supply Connector
5
Inspect water supply connector. Replace
it if it is worn or over 5 years old to prevent flooding
and property damage.
A. Attach water supply coupling nut to fill valve.
A
Turn coupling nut clockwise by hand until tight.
WARNING: Do not over tighten the nut as it could
damage fill valve or coupling nut, resulting in
flooding and property damage. Fluidmaster Click
Seal
®
connector is recommended: A perfect seal
every time without over tightening.
B. Turn on water supply and check for leaks. If you
find leaking at bottom of tank, turn nut just enough
to stop leaking. Then flush toilet to check.
B
IF FILL VALVE TURNS ON AND OFF BY ITSELF
• This indicates the tank is losing water. The fill valve is refilling lost water.
Clean flapper and drain seat. If leak continues change flush valve. Install
Fluidmaster 507AKR, 540AKR or 555C kit.
IF WATER LEVEL IN BOWL IS TOO LOW
• Make sure the refill tube is supplying water down overflow pipe.
• Water level in tank may be too low. Raise water level to 1/2" below top of
overflow pipe (See "ADJUSTING TANK WATER LEVEL"). You may have
to lengthen the fill valve in order to increase the water level in tank (See
"PREPARING THE FILL VALVE FOR INSTALLATION").
• Flapper may be closing too soon. Give flapper chain approximately 1/2"
of slack.
TOOLS
NEEDED
Scissors
TANK LEVER
PARTS
REFILL TUBE
IN THIS KIT:
REFILL CLIP
(1) Fill Valve
FLOAT
(1) Flapper
CUP
(1) Shank Washer
OVERFLOW
PIPE
(1) Locknut
LOCK RING
(1) Refill Tube
FLUSH
FILL
(1) Refill Clip
VALVE
VALVE
FLAPPER
TANK SHOULD
LOOK LIKE THIS
WHEN SET UP IS
LOCKNUT
COMPLETE
Adjusting Tank Water Level
6
With water turned on, set float cup to
desired level, by turning water level adjustment
screw. When adjusting float cup, flush tank first.
Then make adjustment while tank is filling.
To adjust tank water, turn adjustment screw
clockwise to raise water level or counter
clockwise to lower water level. Once adjusted,
flush toilet and check new level. Repeat if
necessary.
HINT: When you twist adjustment screw 8 times
- float moves 1/2".
Removing Valve Cap Assembly, Flushing Out Debris, Replacing Seal, & Replacing Valve Cap Assembly
Removing Valve Cap Assembly
Turn off water supply
& flush out tank. Push
float up with right hand
(see picture). Grip and
hold shaft under float
with right hand. With left
hand, twist cap and lever
counter clockwise 1/8th
of a turn to unlock the top
cap. Pressing down on top
may be helpful with older
valves. Let cap assembly
hang on float cup.
242
SEAL
30800 Rancho Viejo Road, San Juan Capistrano, CA 92675
Contact Fluidmaster for troubleshooting help or visit www.fluidmaster.com
Sponge
Remove Old Fill Valve & Flapper
1
C
Remove tank lid. Use pencil to mark water level of
tank. Then follow steps A-E.
A. Turn off water supply (Clockwise). Flush toilet and remove
excess water from tank with sponge.
B. Remove water supply coupling nut. Remove locknut from
under tank.
C. Remove fill valve from tank.
B
D. Unhook flapper chain from tank lever.
E. Remove flapper from overflow pipe on flush valve.
D
A
Installing New Fill Valve
3
Place fill valve in tank. Make sure lid will sit on top of tank without
touching valve. Align fill valve nipple to face center of tank. Press down on
shank from inside tank while tightening locknut.
Hand-tighten only. DO NOT OVER TIGHTEN. Over
tightening may crack the fill valve or tank causing
flooding. Make sure the float cup does not touch
the tank walls or tank lever and flush valve.
Attach one end of refill tube to refill clip. Place clip
on right side of overflow pipe. Attach other end of
tube to nipple on fill valve with a slight arch (See
drawing to the right). Cut tube as necessary.
WARNING: Do not shove refill tube down overflow
pipe. This may cause significant water waste.
Code Compliance
7
Once fill valve is installed, ensure overflow
pipe and water level of tank are correctly set.
1. THE TOP OF OVERFLOW PIPE (A) must be
minimum of 1" below TANK LEVER HOLE (B).
2. WATER LEVEL (C) is set below top of Overflow
Pipe (Fluidmaster recommends 1/2").
3. THE CRITICAL LEVEL MARK / C.L. Mark (D)
identified by C.L. on fill valve must be positioned 1"
above top of overflow pipe. This is a requirement of
the Universal Plumbing Code.
Code Compliance helps protect your home &
drinking water supply.
Flushing Out Debris
If Replacing
Seal
Hold cup upside down over
uncapped valve to prevent
splashing. Turn water supply
on and off a few times.
Turn water supply off when
putting cap back on valve.
SEAL
LOCATION
If Replacing Seal:
Use only a genuine
Fluidmaster 242 seal.
www.Fluidmaster.com • 800-631-2011
M-F 5:30 am - 5:00 pm PST.
E
Correct set up of refill
tube and refill clip to
overflow pipe
REFILL TUBE
NIPPLE
REFILL
CLIP
D
B
WATER
LEVEL
A
C
OVERFLOW
FILL
PIPE
VALVE
Replacing Valve Cap
A. Place cap assembly on top of gray valve
body by aligning cap arm and adjustment
rod next to refill tube.
B. Press down on top cap while rotating
top & arm clockwise to locked position.
A
B

Publicidad

loading

Resumen de contenidos para Fluidmaster 400C

  • Página 1 LIMITED FIVE-YEAR EXPRESS WARRANTY FLAPPER Subject to the “Exclusions” set forth below, Fluidmaster Inc. promises to the consumer to repair, or at the option of Fluidmaster Inc. to replace any TANK SHOULD part of this plumbing product which proves to be defective in workmanship or materials under normal use for five years from the date of purchase. All LOOK LIKE THIS costs of removal, transportation and reinstallation to obtain warranty service shall be paid by the consumer.
  • Página 2 PERSONALES O CUALQUIER OTRO DAÑO QUE OCURRA DEBIDO AL ABUSO O USO INDEBIDO DEL PRODUCTO, ASÍ COMO POR APRETAR EXCESIVAENTE, POR EL USO DE PIEZAS QUE NO SON DE FLUIDMASTER INC., O POR NO INSTALAR O MANTENER ESTE PRODUCTO DE PLOMERÍA CONFORME A LAS INSTRUCCIONES ESCRITAS, LO QUE INCLUYE EL USO DE PIEZAS QUE NO SON FLUIDMASTER.