  • Página 1 QUICK Install Guide K-400H-001 PerforMAX ® FILL VALVE & SEAL KIT VIDEO HOW-TO VIDEO VISIT: FLUIDMASTER.COM K-400H-001 PRODUCT PAGE *See back page for important legal information. SPANISH - Page 17 INSTALL WITH CONFIDENCE...
  • Página 2: Getting Started

    GETTING STARTED PARTS OVERVIEW TOOLS NEEDED Refill Tube Clamp Towel Bucket Tank Water Level Adjustment Screw Sponge Scissors Bowl Water Level Adjustment Roller Clamp Refill Tube TOP DOWN VIEW Refill Tube Clamp Refill Clip Bowl Water Level Adjustment Tank Water Level Roller Clamp Adjustment Screw Shank Washer...
  • Página 3 STEP 1: PREPARE TANK A: TURN OFF WATER TURN CLOCKWISE B: DRAIN WATER Flush toilet to drain most of the water from the tank. FLUSH C: USE SPONGE OR TOWEL TO SOAK UP EXCESS WATER IN TANK Sponge Towel...
  • Página 4 STEP 2: REMOVE & REPLACE FLUSH VALVE SEAL See below for your specific flush valve seal replacement instruction. For more detailed instructions and installation videos, please visit our website at Fluidmaster.com & enter K-400H-001 in the search field. Kohler AquaPiston ®...
  • Página 5 STEP 3: REMOVE OLD FILL VALVE A: REMOVE CONNECTOR Remove water supply connector from bottom of fill valve by twisting connector nut to the left LEFT (clockwise). NOTE: Inspect water supply connector. Replace it if it is worn, or you don’t know how old it is, to Towel prevent flooding and property damage.
  • Página 6 STEP 4: ADJUST HEIGHT OF NEW FILL VALVE A: TWIST FILL VALVE TO ADJUST HEIGHT Top of fill valve cap should measure roughly 3" above top of overflow pipe when installed. NOTE: Increasing height allows more water to fill in the tank. HOLD Do Not Move Lock Ring TWIST...
  • Página 7 CHAMPION 3: ® Push refill tube onto refill clip, then attach refill clip to flush valve overflow pipe. Reuse original refill clip. Do not use Fluidmaster ® refill clip. NOTE: If refill tube is too long to fit inside tank Scissors with lid closed, cut tube.
  • Página 8 STEP 5: INSTALL NEW FILL VALVE D: INSERT FILL VALVE Position refill tube to face flush valve making sure fill valve parts do not interfere with lever arm. Fill Valve Refill Tube Flush Valve Lever Arm Fill Valve Refill Tube Flush Valve Lever Arm INSTALL LOCKNUT...
  • Página 9 STEP 6: FINISHING STEPS A: ATTACH WATER SUPPLY CONNECTOR TO FILL VALVE Twist to the right (counterclockwise) *Hand-tighten only. DO NOT OVER RIGHT TIGHTEN. TURN ON WATER Check for leaks. (See Troubleshooting for leak solutions) TURN COUNTER- CLOCKWISE C: WATER LEVEL After the tank stops filling, water level should fill the tank to roughly ½...
  • Página 10 STEP 7: FINE-TUNE TANK WATER LEVEL A: FLUSH THE TOILET TO CHECK THE TANK WATER LEVEL After the water stops filling the 1/2" tank, the water level should be roughly ½ inch below the top Overflow of overflow pipe to ensure a Pipe proper flush.
  • Página 11 STEP 8: FINE-TUNE BOWL WATER LEVEL A: FILL BOWL WITH A GALLON OF WATER Wait 1 minute until the bowl water level recedes down and stops. B: MARK THE WATER LEVEL IN THE BOWL With a pencil, draw a line at the top of the water level in bowl.
  • Página 12 STEP 8: FINE-TUNE BOWL WATER LEVEL If the water level matches the line in TOO HIGH the bowl and the fill valve is STILL FILLING, then the bowl water level is TOO HIGH, proceed to Step 8D. If the valve shuts off and the water TOO LOW level does NOT match the line in the bowl, the water level is TOO LOW,...
  • Página 13 A: FLUSH THE TOILET If you’re satisfied with the flush, YOU’RE DONE! YOU DID IT! We knew you could! Share your success story with friends and family! #FixedMyToilet #Fluidmaster Still not working exactly right? See the next page for Troubleshooting.
  • Página 14 TROUBLESHOOTING IF THE FILL VALVE: • DOES NOT TURN ON • WON’T TURN OFF • WON’T REFILL TANK REMOVE CAP AND CHECK FOR DEBRIS Turn off water supply. TURN Flush toilet. COUNTER- CLOCKWISE With right hand push float up, grip and hold shaft under float.
  • Página 15 REPLACE FILL VALVE SEAL Remove cap (see page 14). Replace seal with a genuine Fluidmaster 242 Seal. Replace valve cap. • Place cap assembly on top of gray valve body by aligning cap arm and adjustment rod next to refill tube.
  • Página 16 Insert into hole. Turn 1/4 clockwise to lock. 7. Replace refill tube back into cap. For installation assistance, contact our ADDITIONAL technical services department. Email, QUESTIONS? chat or call our toll-free number. www.fluidmaster.com/support 1-800-631-2011 Hours Available: Monday – Friday 5:30 AM - 5:00 PM PST...
  • Página 17 K-400H-001 VÁLVULA DE LLENADO Y KIT DE SELLOS VIDEO PerforMAX ® VIDEO DE CÓMO HACERLO VISITE: FLUIDMASTER.COM INSTALE CON CONFIANZA PAGINA DE ESPECIFICACIONES DEL PRODUCTO K-400H-001 *Consulte la última página para obtener información legal importante. HERRAMIENTA NECESARIA VISTA DESDE ARRIBA...
  • Página 18 Consulte a continuación para su instrucción específica para el reemplazo del sello de la válvula de descarga. Para instrucciones más detalladas y videos de instalación, por favor visite nuestro sitio web en Fluidmaster.com & ingrese K-400H-001-P5 en la barra de búsqueda. AquaPiston Kohler (use el sello AMARILLO): ®...
  • Página 19: Paso 3: Remueva La Válvula De Llenado Antigua

    PASO 3: REMUEVA LA VÁLVULA DE LLENADO ANTIGUA (PÁGINA 5) REMUEVA EL CONECTOR. Remueva el conector del suministro de agua de la parte inferior de la válvula de llenado girando la tuerca del conector hacia la izquierda. NOTA: Revise el conector del suministro del agua. Cámbielo si esta gastado, o usted no sabe qué...
  • Página 20: Para El Champion 4 De American Standard

    Reutilice el clip de relleno original. No use el clip de relleno de Fluidmaster ® NOTA: Si la manguera de relleno es muy larga para caber dentro del tanque con la tapa cerrada, corte la manguera.
  • Página 21: Paso 7: Ajuste El Nivel Del Agua Del Tanque

    PASO 7: AJUSTE EL NIVEL DEL AGUA DEL TANQUE (PÁGINA 10) DESCARGUE EL SANITARIO PARA REVISAR EL NIVEL DEL AGUA DEL TANQUE. Después que el tanque termine de llenar, el nivel del agua debe ser aproximadamente 1,27CM más abajo de la parte superior del tubo de desagüe para asegurar una descarga apropiada.
  • Página 22 Si está satisfecho con el descargue, ¡TERMINÓ! ¡LO LOGRÓ! ¡Sabíamos que podía! ¡Comparta su historia de éxito con sus amigos y familia! #FixedMyToilet #Fluidmaster ¿TODAVÍA NO FUNCIONA EXACTAMENTE BIEN? CONSULTÉ LA SIGUIENTE PÁGINA PARA SOLUCIÓN DE PROBLEMAS. SOLUCIÓN DE PROBLEMAS (PÁGINA 14) SI LA VÁLVULA DE LLENADO:...
  • Página 23: Solución De Problemas

    REEMPLACE EL SELLO DE LA VÁLVULA DE LLENADO Remueva la tapa. Reemplace el sello con un sello genuino 242 de Fluidmaster. Vuelva a colocar la tapa de la válvula. • Coloque el ensamble de la tapa sobre el cuerpo gris de la válvula alineando el brazo de la tapa y el tornillo de ajuste al lado de la manguera de relleno.
  • Página 24 SOLUCIÓN DE PROBLEMAS EL NIVEL DEL AGUA EN LA TAZA DEL SANITARIO ESTÁ DEMASIADO BAJO (PÁGINA 16) EL AGUA DE LA MANGUERA DE RELLENO TIENE QUE FLUIR A TRAVÉS DEL TUBO DE DESAGÜE Asegúrese que la manguera de relleno este supliendo agua dentro del tubo de desagüe.
  • Página 25 ¿PREGUNTAS ADICIONALES? Para asistencia para la instalación, comuníquese con nuestro departamento de servicio técnico. Email, chat o llame a nuestro número gratuito. www.fluidmaster.com/support 1-800-631-2011 Horario Disponible: Lunes – Viernes 5:30 AM - 5:00 PM Hora Estándar del Pacífico...
  • Página 26 NOTES / NOTAS:...
  • Página 27 NOTES / NOTAS:...
  • Página 28 SIN ANULAR la GARANTÍA DE FLUIDMASTER, ya que este sistema no daña los componentes. NO apriete demasiado las tuercas o el tanque, ya que la taza se puede agrietar. Siempre use piezas de calidad Fluidmaster al instalar o reparar. Fluidmaster no se hace responsable por el uso de piezas durante la que no sean de Fluidmaster durante la instalación o reparación.