Adjust the position of the nail holder according to the
length of the nail. (Fig. 2)
For
adjustment,
turn
counterclockwise about 90 degrees. Move the nail
holder 2 up and down, adjust to the length of a nail
to be used, and adjust the surface of the nail holder
to the marked position of the magazine.
Turn the nail holder 3 clockwise (about 90 degrees)
until it goes click. (Fig. 3)
Magazine
For 45,50mm
For 57,65mm
For 75mm
For 90mm
Load the nails in the magazine. Load the nails in the
magazine. At this time, if the wound portion of nails
is inserted after it is once pulled out beforehand, the
subsequent work can be much facilitated. (Fig.4)
Nagagine
Opening
Close the cover after confirming that the nails are
loaded in the magazine.
Cover
Magazine
Nail Holder
Fig. 2
the
nail
holder
Nail Holder
Fig. 3
Magazine
Cover
Nail
Fig. 4
NOTE:
Before loading the nails in the magazine, position the
nail holder according to the length of the nail. If the
nail holder position is not adjusted, the nail jams. If
the cover is forcibly closed without adjusting the
position of the nail holder, the nail holder may be
damaged.
(2) Load nails in the guide
Extend the nail line from the magazine.
Insert the first nail into the driving hole and the
second nail between the pawls of the feeder. Insert
the nail so that the nail head engages the guide slot.
(Fig. 5)
Nail Guide
1
Feeder
Nail outlet
(3) Close nail guide
After making sure that the magazine cover is closed,
hook your finger to the nail guide and the knob, and
while pushing the knob down, turn the nail guide
clockwise to completely close it. (Fig.6)
The above operation completes the loading of nails.
Knob
Nail Guide
NOTE:
The nail guide may not close properly or the nails
may not advance properly if the linked bands or nails
do not enter into the indicated position or the nails
come away from the guide surface or the wire linking
the nails is warped.
English
First Nail
Guide Slot
Feeder
Guide Surface
Fig. 5
Cover
Fig. 6
4