Installation Instructions
Opening the CO
•
Make sure the secondary shut-off valve (shown in Fig. 9 in "open" position) is closed. To open the main CO
valve, slowly turn the main valve counter-clockwise until fully open.
•
Notice the needle on the regulator gauge start to climb.
Adjusting the CO
The gauge (closest to the CO
psi (see Fig. 10). The pressure can be adjusted as needed.
•
Release adjustment lock nut marked 2.
•
Turn regulator nut marked 3.
- To increase pressure, turn nut clockwise.
- To decrease pressure, turn nut counter-clockwise.
•
Retighten lock nut marked 2.
•
Open secondary shut off valve to let CO
•
Allow several minutes for the keg to properly pressurize. Regulator gauge may drop while this happens. (Note: Listen
for hissing along all connections to identify if there are any leaks).
Rubber washer goes
here
Fig. 7
Spanner Faucet Wrench (Included)
•
Spanner faucet wrench (provided) is for either removing or tightening the connection.
Note: To prevent leakage, use the provided wrench to further tighten the faucet.
Cylinder Main Valve
2
Regulator
2
cylinder) monitors low internal keg pressure and should be adjusted to read between 8-12
2
fl ow into the keg.
2
IMPORTANT: Please put
rubber washer on the
coupler to avoid any
leaks.
Fig. 8
Fig. 9
Fig. 9
Fig. 9
10
cylinder
2
Fig. 10