CYLINDERS
1.
Unpack and ensure all included parts are present.
2.
Unscrew 2x mounting hardware from driver mounting
plate, separate the Luminaire Disconnect to separate
driver mounting plate from fixture assembly.
3.
Connect building AC supply wires from junction box to
input wire side of LED driver with push nuts (included).
Connect ground wire to junction box. Ensure excess
ground wire can extend out of junction box.
N
ote:
Junction boxes must be min size of 2-1/8" deep
and 4" square. Recommended Junction boxes are
Crouse-Hinds part numbers TP403, TP432, TP434,
TP438, TP395, or equivalent.
Driver
Push Nuts
Figure 4.
Figure 5.
Driver Mounting Plate
Luminaire Disconnect
RD
BK
GN
Ground Wire
Mount Plate and Gasket
Fixture Assembly
Driver Mounting Plate
BK
Ground Wire
Mount Plate and Gasket
Fixture Assembly
COOPER LIGHTING SOLUTIONS
Installation Instructions - WIS - Lumiere Instructions
4.
Separate and route Luminaire Disconnect and ground
wire out of center hole in driver mounting plate. Attach
driver mounting plate to existing junction box with
proper hardware (not included).
5.
Re-connect ground wire and Luminaire Disconnect to
fixture assembly.
6.
Attach mount plate and gasket to driver mounting
plate with 2x mounting hardware. Ensure adequate
gasket compression to provide proper seal from the
environment.
Mounting Hardware
Knuckle
9000-W1 Series
Luminaire Disconnect
RD
GN
9000-W2 Series
Mounting Hardware