Descargar Imprimir esta página

ESAB PEI Instrucciones De Uso página 55

Ocultar thumbs Ver también para PEI:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
GB
Voltage setting knob, R1
Intended for setting the voltage of the welding
power source.
The 0--10 V reference signal is produced by
positioning the knob.
Voltage meter
It shows an average value of the arc voltage. The meter doesn't show any voltage
less than 10V.
The reading is frozen at the moment of switching the welding process off.
Wire feed speed setting knob, R2
Intended for setting the wire speed.
Inching toggle switch, S5
Operation of this switch is disabled during the
welding. The control system doesn't allow for
quick switching from one to opposite direction to
protect the drive.
Ammeter
It shows the average value of the welding current. The meter doesn't show any
current below 10A.
The reading is frozen at the moment of switching the welding process off.
The ammeter is intended for different types of shunts. The unit is set to 1000A,
60mV before leaving the factory.
Wire speed display
The display shows the set wire speed. The range is changed according to setting the
SAW or MIG/MAG mode. The speed can be displayed in m/min or in inch--per--min
(IPM). N.B. The display is set to m/min at delivery, if you want to change to IPM
contact ESAB.
The range for SAW is 1.0 -- 9.0 m/min, (40--355 IPM),
S
The range for MIG/MAG is 1.8 -- 16.2 m/min, (70--640 IPM).
S
Travel speed setting knob, R3
Intended for setting the travel speed.
Travel speed display
Intended for showing the travel speed.
The maximum displayed value is 200cm/min (80IPM).
N.B. The display is set to cm/min at delivery,
if you want to change to IPM contact ESAB.
Travel direction toggle switch, S6
For setting the direction of travel.
Welding stops if the direction of travel is changed during the welding process.
fgc6d2ea
- - 55 - -

Publicidad

loading