TECHNICAL DATA
Voltage range ......................................................12 V
Quick charge current ..........................................3.0 A
Maintaining charge ............................................500 mA
Battery charging time Li-Ion 1.5 Ah ....................30 min
Weight according EPTA-Procedure 01/2003 .....460 g
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Please pay attention to the safety instructions in the
attached leafl et!
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors offer to
retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only System C 12 chargers for charging System C 12
battery packs. Do not use battery packs from other systems.
The following battery packs can be charged with this
charger:
voltage
battery
12 V
C12 B
12 V
C12 BX
12 V
M12 B
12 V
M12 BX
12 V
M12 B2
12 V
M12 B3
12 V
M12 B4
12 V
M12 B2
12 V
M12 B6
Do not try to charge non-chargeable batteries with this
charger.
No metal parts must be allowed to enter the battery section
of the charger (short circuit risk).
Never break open battery packs and chargers and store
only in dry rooms. Keep dry at all times.
Do not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new
one.
Before use check machine, cable, and plug for any
damages or material fatigue. Repairs should only be carried
out by authorised Service Agents.
This appliance is not intended to
be used or cleaned by persons
with reduced physical, sensory or
mental capabilities, or lack of
experience or knowledge, unless
they have been given instructions
concerning the safe use of the
appliance by a person legally
responsible for their safety. They
should be supervised whilst using
6
ENGLISH
289 078 - C12C.indd 6
289 078 - C12C.indd 6
CHARGER
rated
No. of
capacity
battery
cells
≤ 1.5 Ah
3
≤ 3.0 Ah
2 x 3
≤ 1.5 Ah
3
≤ 3.0 Ah
2 x 3
≤ 2.0 Ah
3
≤ 3.0 Ah
3
≤ 4.0 Ah
2 x 3
≤ 2.0 Ah
3
≤ 6.0 Ah
2 x 3
the appliance. Children shall not
use, clean or play with this
appliance, which when not in use
should be secured out of their
reach.
SPECIFIED CONDITIONS OF USE
The quick charger can charge Milwaukee batteries from C
12 to 12 V.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
BATTERIES
Battery packs which have not been used for some time
should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
CHARACTERISTICS
After inserting the battery into the reception of the charger
the battery will automatically be charged (red lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once
the battery reaches the correct charging temperature
(0°C...60°C).
Charging time varies depending on the battery temperature,
charge needed and the type of battery pack being charged.
As soon as charging is completed, the charger switches
over to "trickle" charge to maintain the full capacity (green
control lamp is illuminated continuously, red lamp off)
It is not necessary to remove the battery after charging. The
battery can be stored permanently in the charger without the
danger of being overcharged.
If both LEDs fl ash at the same time, either the battery has
not been completely mounted or there is a fault in the
battery or the charger. For safety reasons you must stop
using the charger and battery immediately and have them
inspected by an Milwaukee Customer Service Centre.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in
accordance with local, national and international provisions
and regulations.
• The user can transport the batteries by road without
further requirements.
• Commercial transport of Lithium-Ion batteries by third
parties is subject to Dangerous Goods regulations.
Transport preparation and transport are exclusively to be
carried out by appropriately trained persons and the
process has to be accompanied by corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and
insulated to prevent short circuit.