MONOBLOC 100L

2.4. Technical Data

Equipment type
Tank Rated Capacity
Weight Empty
Cylinder Material
Outer Plate
Insulation
Corrosion Protection
Maximum Water Temperature
Maximum Operating Pressure
Test Pressure
Heat Loss
Protection
Electric Supply
Electrical Power HP (med / max)
Electrical Element
Thermal power HP
Fan Power
Maximum Operating
Max Temperature DWH (HP)
Max Temperature DWH (Backup)
Fluid
Tapping Profile
COP
1
Heating Time
1)
Max. Water in Single Intake 40 °C
Energy Class - ErP
1)
Energy Efficiency
1)
Annual Energy Consumption
Outside Air Temperature (Min/Max)
Indoor Sound Level
Air Flow Rate
Maximum Duct Length
1) A20/W10-54, according EN16147 and delegated regulations (EU) Nº812/2013

3. TRANSPORT

Transporting the equipment must be carried out with an inclination below 45
The equipment must be raised and lowered with extreme care to avoid impact that
could damage the material;
Make sure the belts and/or transportation straps do not damage the material;
Always use means of transportation suitable for the equipment (pallet lift, forklift,
etc...);
WARNING
38
Unit.
L
Kg.
-
-
-
-
C
0
bar
bar
kWh/24h
-
-
W
W
W
W
A
C
0
C
0
-/kg
-
-
(HH:mm)
L
1)
-
%
kWh/year
1)
C
0
dB(A)
m
/h
3
m
Technical Manual
100l
Heat Pump Air/Water for DWH
100
70
Enamelled Steel
Sheet Metal
High Density Polyurethane 50mm
Yes (Magnesium Anode)
80
7
10
0,95
IPX1
220-240 V / single phase / 50 Hz
400/650
1000
1800
65
3,2 + 4,4 (with electrical element)
55
70
R 134a / 1,1
M
2,8
02:20
109
A+
117
437
-5/40
51
450
8
;
0