The equipment must be transported in its original package to the place of installation. Check, before begin-
ning transport of the external unit, if the path you will travel is unobstructed, in order to prevent collisions
that could cause damage to the device.
The packages contain the following information symbols:
Fragile, handle with extreme caution
Make sure the arrows are always up

4. INSTALLATION

4.1. Safety Device

4.1.1. Pressure gauge of high/low pressure

In case of running outside the range of pressures recommended and defined by the supplier, the equip-
ment will switch off and indicate error in the electronic panel.

4.1.2. Safety Thermostat

The safety thermostat is set by the supplier to ensure that the water temperature in the storage water
heater does not exceed the standard value. Should the temperature exceed this value, the thermostat
switches off the support resistance. Switching on is done manually by qualified staff, after analyzing the
reasons for the switch off.

4.1.3. Corrosion Protection

The storage water heater in Enamelled. Besides being resistant to corrosion, the storage water heater
has in addition a magnesium anode that should be checked periodically according to information by the
installer.

4.1.4. Expansion Vessel*

The expansion vessel is a device whose purpose is to compensate for the increase in water volume due
to temperature rise.
Installing this device is recommended procedure for a correct installation of the
equipment.
Installing this device is the responsibility of the installer.
As a general rule it is installed in the cold water pipe.