Cadet The Hot One RCP502S Guía Para El Propietario página 4

El calentador the hot one
Ocultar thumbs Ver también para The Hot One RCP502S:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. The heater must be properly installed before
it is used. Be sure the plug fits tightly into the
receptacle. The red light indicates the unit is
plugged in.
2. Do not operate without the stand attached.
3. Do not use breaker panel or wall thermostat to
control heater.
How to Operate Your Heater
1. Select the "LOW" wattage setting. If your desired temperature is not reached, select the "HI" setting.
NOTE: The temperature of the air coming from the front of the heater will be approximately 40˚F warmer than the room temperature, in
the "HI" setting. With extremely cold environments, air from the heater may not feel hot. As the heater continues to operate, the heater
air and surrounding air temperature will continue to increase.
2. Select 'AUTO' to operate the heater with the thermostat.
3. Turn the thermostat fully clockwise. The heater will start.
NOTE: The fan will operate approximately 20 seconds after startup. This allows the elements to heat before blowing air, eliminating cold
startups. Fan operation will continue for approximately 90 seconds after elements shut off to disperse residual heat.
4. When the room reaches your comfort level, turn the thermostat knob counter clockwise until you hear a click sound. The heater will
automatically cycle around this preset temperature.
5. To reduce the room temperature, turn the knob counter clockwise. To increase the room temperature, turn the knob clockwise.
"ON" SETTING
The fan can be operated continuously when set to the "ON" position. For cooling or air circulation (when no heat is desired), turn the
thermostat to the 'OFF' position by rotating the thermostat knob counter clockwise.
NOTE: If the thermostat is turned to a setting above room temperature, the elements will turn on and heat the area until the
temperature reaches that set point. Once the elements go off, the fan will continue to run. This cycle will continue.
About the Manual Reset Temperature Limit Control
The heater is protected by a high temperature manual reset control, designed to open the heater circuit
when excessive operating temperatures are detected.
Resetting the Manual Reset Temperature Limit Control
If the manual reset limit control has opened the heater circuit due to excessive operating temperatures,
the heater will not work or may blow cold air until the limit reset button is pressed. After allowing the
unit to cool for at least 10 minutes and resolving the problem causing the limit to trip (typically the heater
is blocked or needs cleaning); use a narrow object such as a ball-point pen to access the reset button
through the lower-right hole marked "RESET". Press FIRMLY. If the manual reset continues to trip, see
Troubleshooting Chart.
For more effective and safer operation and to prolong the life of
the heater, read the Owner's Guide and follow the maintenance
instructions. Failure to properly maintain the heater will void any
warranty and may cause the heater to function improperly. War-
ranties are non transferable and apply to original consumer only.
Warranty terms are set out below.
LIMITED FIVE-YEAR WARRANTY: Cadet will repair or replace
any Hot One (RCP) heater found to be defective within five years
after the date of purchase.
These warranties do not apply:
1. Damage occurs to the product through improper installation or
incorrect supply voltage;
2. Damage occurs to the product through improper maintenance,
misuse, abuse, accident, or alteration;
3. The product is serviced by anyone other than Cadet;
4. If the date of manufacture of the product cannot be deter-
mined;
5. If the product is damaged during shipping through no fault of
Cadet.
6. CADET'S WARRANTY IS LIMITED TO REPAIR OR RE-
PLACEMENT AS SET OUT HEREIN. CADET SHALL NOT BE
LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR
FOR CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL EX-
PENSES RESULTING FROM BREACH OF THESE WRITTEN
WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY.
Page 4
OPERATING INSTRUCTIONS
Resetting the Manual Reset Limit Control
Warranty
4. Always unplug heater when not in use.
5. Clean heater at least every six months or as
required. See "Maintaining Your Heater".
6. CAUTION: Risk of electrical shock. Do not
open. No user-serviceable parts inside. Any
other service not detailed in this owner's guide
should be performed by an authorized service
representative.
7. IN THE EVENT CADET ELECTS TO REPLACE ANY PART
OF YOUR CADET PRODUCT, THE REPLACEMENT PARTS
ARE SUBJECT TO THE SAME WARRANTIES AS THE PROD-
UCT. THE INSTALLATION OF REPLACEMENT PARTS DOES
NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES.
REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR
PART DOES NOT CREATE ANY NEW WARRANTIES.
8. These warranties give you specific legal rights, and you may
also have other rights which vary from state to state. Cadet nei-
ther assumes, nor authorizes anyone to assume for it, any other
obligation or liability in connection with its products other than as
set out herein.
If you believe your Cadet product is defective, please contact
Cadet Manufacturing Co. at 360-693-2505, during the warranty
period, for instructions on how to have the repair or replacement
processed. Warranty claims made after the warranty period has
expired will be denied. Products returned without authorization
will be refused.
Parts and Service
Visit cadetheat.com/parts-service for information on where to
obtain parts and service.
Reduce-Reuse-Recycle
This product is made primarily of recyclable materials. You
can reduce your carbon footprint by recycling this product at
the end of its useful life. Contact your local recycling support
center for further recycling instructions.
Manual Reset Limit Button

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

The hot one rcp402s

Tabla de contenido