Technical Data - Grohe Europlus E 36 207 Manual Del Usario

Ocultar thumbs Ver también para Europlus E 36 207:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
GB
Fold out pages:
Please pass these instructions on to the fitting user!
Application
Prod. No. 36 208:
Single-hole mixer suitable for:
• Direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Prod. No. 36 207, 36 232 and 36 236:
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.

Technical data

• Flow pressure
• Operating pressure
• Test pressure
If static pressure exceeds 5 bar, a pressure-reducing valve
must be fitted.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 3 bar flow pressure:
• Hot water supply temperature
Recommended (energy saving):
• Voltage supply:
• Automatic safety shut-off (factory setting):
• Run-on time (factory setting):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape
factory setting):
• Type of protection:
• Battery check:
• Water connection
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature for ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Special accessory (infrared remote control)
• Infrared remote control (Prod. no. 36 206) for changing the
factory settings.
3
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
min. 0.5 bar / recommended 1 - 5 bar
max. 10 bar
16 bar
Approx. 6 l/min
max. 70 °C
60 °C
6 V-lithium battery (type CR-P2)
60 s
1 s
Approx. 13cm
IP 59 K
Flashing signal
cold - right
hot - left
A
2
2500 V
100 °C
Installation
Flush pipes thoroughly!
Fitting
Refer to the dimensional drawings on fold-out page I.
Lift rod (A) must be inserted into the mixer body during
installation, see fold-out page II, Fig. [1].
Fasten fitting to wash basin, see Figs. [1] to [3].
Install pop-up waste (28 915), see fold-out page I.
Seal plug-hole rim.
Connection
The cold water supply must be connected on the right, hot
water supply on the left.
In order to ensure permanent, trouble-free operation, fitting of
the enclosed adaptor is mandatory.
Insert filter (B) and screw adaptor (C) together with seal (C1)
onto the service valve, see Fig. [4].
Open cold and hot-water supply and check connections
for water-tightness.
Setting the temperature limiter
Prod. No. 36 207 and 36 236:
1. Remove screw (D), see Fig. [5].
2. Turn mixer lever (E) clockwise until the desired maximum
temperature is reached.
3. Detach mixer lever (E), see Fig. [6].
4. Detach stop ring (F) and reattach with notch (F1) pointing
vertically upwards.
5. Turn mixer spindle (G) anti-clockwise to the stop.
6. Attach mixer lever (E) in horizontal position and fasten with
screw (D).
Prod. No. 36 232:
1. Remove screw (H), see Fig. [7].
2. Pull off stop ring (I).
3. Turn mixer spindle (J) clockwise with screwdriver until the
desired maximum temperature is reached.
4. Refit stop ring (I) and secure using a screw (H).
Operation
The infrared-electronics are adjusted so that water flow is
initiated when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Note:
As instructions for use, we recommend affixing the enclosed
sticker in public areas.
Automatic safety shut-off
After 60 s (factory setting) of continuous detection of an object,
the infrared electronics automatically stop the water flow.
Automatic flushing (factory setting: not activated)
The automatic flushing serves to maintain water hygiene in the
case of long-term non-utilisation of the fitting. It activates water
flow for 1 - 10 minutes, 1 or 3 days after the last use.
Safety notes:
- Ensure free draining in the case of activated automatic
flushing.
- For automatic flushing of the hot and cold water lines, the
fitting must be in the mixed water setting.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Europlus e 36 208Europlus e 36 232Europlus e 36 236

Tabla de contenido