Technical Data; Noise And Vibration Information; Intended Use - Würth 0891 106 3 Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Device elements (Fig. I)
1 Adjustable nozzle
2 Lock nut
3 Hanging hook
4 Trigger lever
5 Handle
6 Compressed air connection R 1/4" inside
7 Riser pipe
8 Threaded fitting for 1 l container

Technical Data

Item
Air consumption:
Working pressure:
Max. pressure:
Recommended hose length
Min. inside diameter
Compressed air connection:
A pressure reducer, a filter and a shut-off valve for
shutting off the air supply are required in the system.

Noise and Vibration Information

The equivalent continuous sound pressure level,
calculated on the A scale, is measured at a horizon-
tal distance of 50 cm. For bituminous products, this
level is <80 dB(A).

Intended Use

The device is intended for use in spraying bitumen,
rubber, plastic, synthetic resin and wax-based liquid
underseal/stone chip protection from special con-
tainers. The device is intended for use with genuine
Würth system accessories. Any other use is consid-
ered an improper use.
The user is solely responsible for damage
resulting from improper use.
Use of the Container
Regulation of the Spray Rate
0891 106 3
Structure and spraying rate are controlled by regu-
180 - 220 l/min
lating the adjustable nozzle [1].
The standard spraying distance is approx. 10 - 30 cm.
3 - 4 bar
8 bar
10 m
6 mm
R 1/4" inside
Operation (Fig. II)
Check the shelf life of the product.
Screw in the container in clockwise direction.
Connect the device to the air supply.
• Observe the technical data!
Point the device at the surface to be sprayed
from a distance.
Press the trigger lever.
For smaller areas and repairs, turn the adjust-
able nozzle [1] in clockwise direction.
• Spraying distance: approx. 10 cm
For wider spray application on larger surfaces,
turn the adjustable nozzle [1] in anti-clockwise
direction.
• Spraying distance: approx. 30 cm
Turn lock nut [2] in anti-clockwise direction up
to the stop.
The position of the adjustable nozzle is fixed.
After use, disconnect the device from the air
supply and clean (see section Maintenance /
Care).
9

Publicidad

Tabla de contenido
loading

Tabla de contenido