Save Power Mode
To activate or deactivate Save Power
Mode, follow the below steps:
1.Open the door and press Half Load (4)
and Delay (5) buttons simultaneously for 3
seconds.
2.After 3 seconds, the machine will display
last Setting, "IL1" or "IL0".
3.When Save Power Mode is activated,
"IL1" will be displayed. On this mode,
interior lights will turn off 4 minutes after the
door is opened, and the machine will turn
off after 15 minutes of no activity in order to
save energy.
4. When Save Power Mode is deactivated
"IL0" will be displayed. If Save Power Mode
is deactive, interior lights will be on as long
as the door is open, and the machine will
always be on unless it is turned off by user.
5. To save the selected setting, turn off the
machine.
In factory setting, Save Power Mode is
active.
Natural Ion Tech (Model Depending)
This function provides extra hygiene to
the machine thanks to Ion Technology It
operates as an independent program. This
function is activated by pressing Half Load
(4) button for 3 seconds in ready state. At
the end of 3 seconds, "Ion" will be displayed
which indicates Natural Ion Tech function
is activated. The button is released after
"Ion" is displayed. If no intervention by user,
24 hour after activation of Natural Ion Tech
function, it is automatically cancelled.
NOTE: If machine is turned off, Natural
Ion Tech function is cancelled.
NOTE: Natural Ion Tech function does
not work with any program.
Crystalight (Model Depending)
This technology which have Ion and Light
Technology together, provides to extra
hygiene. It prevents bad odor during a
washing program that includes a drying
step.
Crystalight function is activated or
deactivated before starting program in
ready state by pressing Half Load (4) button
for 6 seconds. At the end of 6 seconds,
"UV1" will be displayed which indicates
Crystalight function is activated. When it is
deactivated, at the end of 6 seconds, "UV0"
will be displayed. Crystalight setting follows
Natural Ion Tech setting.
Default set is "UO".
NOTE: If user do not deactivate
Crystalight function at the end of program,
it will remain active until the machine turns
off.
NOTE: If Crystalight or Natural Ion
Tech function is active, Natural Ion Tech led
lights up like dimming during door is open.
Infoled 2.1 (Model Depending)
LED Indicator
Red, continuous
Red, flashing
Red, flashing
rapidly
Green, continuous
EN - 21
State of the Machine
The machine is running a
program.
A program is cancelled.
The machine has a fault. Refer
to section "Automatic fault
warnings and what to do".
A program is finished.
V.1