ALWAYS WASH HANDS WELL WITH SOAP AND WATER BEFORE PUMPING.
Before First Use
If your HygieniKit system is marked "STERILE," open and use.
If your HygieniKit system is NOT marked "STERILE," before first use:
• Boil all parts—except tubing, adapter cap,
and tubing adapter—for 20 minutes.
• Remove all parts from water right after boiling.
• Allow parts to air dry before assembly and use.
NOTE: Before using the HygieniKit system, check the parts for cracks,
chips, tears, color changes, or wear. They can affect the
function of the kit. If parts need replacing due to defects, please call:
In US: 1.866.99.AMEDA (26332)
In Canada: 1.800.604.6225
In other countries: Call your local distributor or the location where you
purchased your pump. For a listing of distributors in your country, please visit www.ameda.com.
After Every Use
Cleaning Pump
Wipe the Purely Yours Breast Pump with clean, damp cloth.
Cleaning HygieniKit
• Take apart HygieniKit system to clean.
• Rinse any milk residue from pump parts
with cool water.
• Wash gently by hand—except tubing,
adapter cap, and tubing adapter—
in warm, soapy water.
• Rinse well with warm, clean water.
Do not insert anything into white valve
while cleaning.
• Allow parts to air dry on clean surface.
Large plastic pieces (breast flanges and bottles) can be washed
on the upper rack of a standard household dishwasher.
6
E N G L I S H
Assembly
Do not boil or wash
tubing, adapter cap,
and tubing adapter.
5
Single and Dual Pumping
The kit can be used to single or dual pump.
Do not boil or wash
tubing, adapter cap,
and tubing adapter.
Insert the tubing adapter into the tubing adapter port of the pump.
To Begin Pumping
• Center nipple(s) in breast flange(s).
• Fill breast flange(s) with the breast(s) to create an air seal.
Starting Pump
• Choose power option, and connect pump to power source.
• Turn SUCTION dial to the right until light turns on. Pump is now on.
2
1. Insert diaphragm into upper chamber
1
of breast flange.
2. Snap adapter cap with tubing onto the top
of upper chamber.
3. Gently push white valve firmly onto ring on
3
underside of breast flange.
4. Screw bottle onto breast flange.
4
5. Push tubing adapter at end of tubing into tubing
adapter port on pump.
To single pump:
Remove one tube
and close tubing
adapter.
Turn dials to the right (clockwise) to
increase pump settings (faster SPEED,
stronger SUCTION). Turn dials to the left
(counter-clockwise) to decrease pump
settings (slower SPEED, gentler SUCTION).
To dual pump:
Both tubes should
be attached to
tubing adapter.
Dual pumping
with one hand
gives you a free
hand for other
things.
7
E N G L I S H