rod arm remains fi rm.
GB
Attention: Never use the motor force to support the weight of
the arm. Always use the balancing spring.
L
(max)
4500
5000
5500
6000 (*)
6500 (*)
7000 (*)
7500 (*)
8000 (*)
(*)
As concern L≥6000 use the fi xed UPAF bearing (or the mobile UPAM bearing).
3.5 Limit switch adjustment
-
(Fig. 2, detail 15) Adjust the rod in the horizontal position
(slightly upwards), mechanically operating the lever in
order to make movement as smooth as possible.
-
(Fig. 6) (Fig. 2, detail 19) Adjust the open/close end-of-
travel pad in order to stop the motor 10-20 mm before it
reaches the lock (*).
(*) with use the barrier recovers the clearance.
ATTENTION: The door of the barrier is impact resistant; it must
always be mounted on the container during the operation of
the barrier.
4.
ELECTRICAL CONNECTIONS AND STAR-
TUP
The electrical connections and the startup of the UP8E barri-
eres are illustrated in the installation manual of the E1A control
panel.
WARNING: set the RF force to the maximum level.
5.
MAINTENANCE
months)
Power off:
-
Clean and oil the external levers and check that the visible
nuts and screws are all well screwed down.
-
Check the electrical connections.
-
Check the manual release.
-
Check springs balancing
Power on:
-
Check the functioning of the limit switches.
-
Check for proper functioning of the obstacle detector.
-
Check the operation of all command and safety functions.
ATTENTION: For spare parts, see the spares price list.
UP8 - IP1782
L
1 green
1 red
1 red + 1 green
1 red + 1 green
2 reds
2 reds
2 reds + 1 green
2 reds + 1 green
PROGRAM
(each
+ Sensitive edge
L
1 red
1 red + 1 green
1 red + 1 green
2 reds
2 reds
2 reds + 1 green
3 reds
/
6
10
+ UPGR
L
=
=
max. 6 m
1 red
1 red + 1 green
2 reds
2 reds
2 reds + 1 green
2 reds + 1 green
3 reds
/