Safety Notes; Important Notes; Functions; Information About Operation - LGB 21672 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Safety Notes

• This model may only be used with the operating system designed for it.
• Use only switched mode power supply units and transformers that are designed
for your local power system.
• This locomotive must never be supplied with power from more than one power pack.
• Pay close attention to the safety notes in the instructions for your operating system.
• Not for children under the age of 15.
• WARNING! Sharp edges and points required for operation.
• WARNING! This product contains magnets. Swallowing more than one magnet
may cause death in certain circumstances. If necessary, see a doctor immediately.

Important Notes

• The operating instructions are a component part of the product and must therefore
be kept in a safe place as well as included with the product, if the latter is given to
someone else.
• The warranty card included with this product specifies the warranty conditions.
• Please see your authorized LGB dealer for repairs or spare parts.
• Disposing: www.maerklin.com/en/imprint.html

Functions

• This model is designed for operation on LGB two-rail DC systems with conventio-
nal LGB DC train controllers or power packs (DC, 0 - 24 volts).
• Factory-installed multiple protocol decoder (DC, DCC, mfx).
• The model is programmed with locomotive address 03 for use with the LGB Multi
Train System (DCC). The locomotive is automatically recognized in operation with mfx.
• Volume can be changed for the sound effects
• Mfx technology for the Mobile Station/Central Station.
Name set at the factory: UP 32168
• The functions can be activated only in parallel. Serial activation of the functions is
not possible (Please note here the instructions for your controller).
Mode of Operation Switch
The rail cleaning locomotive has a two-stage operating mode switch in the driver's
cab (Figure 1), which can be operated through the open window:
Pos. 0
Locomotive de-energized
Pos. 1
Everything switched on

Multi-Protocol Operation

Analog Operation
This loco can also be operated on analog layouts or areas of track that are analog.
The decoder recognizes alternating current (DC) and automatically adapts to the ana-
log track voltage. All functions that were set under mfx or DCC for analog operation
are active (see Digital Operation).
The built-in sound functions come from the factory inactive for analog operation.
Digital Operation
The digital protocol with the most possibilities is the highest order digital protocol.
The sequence of digital protocols in descending order is:
Priority 1: mfx; Priority 2: DCC; Priority 3: DC
Note: Digital protocols can influence each other. For trouble-free operation, we re-
commend deactivating those digital protocols not needed by using CV 50. Deactivate
unneeded digital protocols at this CV if your controller supports this function.
If two or more digital protocols are recognized in the track, the decoder automatically
takes on the highest order digital protocol, example: mfx/DCC; the decoder takes on
the mfx digital protocol (see previous table).
Note: Please note that not all functions are possible in all digital protocols. Several
settings for functions, which are supposed to be active in analog operation, can be
done under mfx and DCC.
Notes on digital operation
• The operating instructions for your central unit will give you exact procedures for
setting the different parameters.
• The values set at the factory have been selected for mfx in order to guarantee the
best possible running characteristics.
Adjustments may have to be made for other operating systems.
4

Publicidad

Tabla de contenido
loading

Tabla de contenido