Selection of the System mode is made in Setup mode, refer to section 3.1.
Additional operational options are available, refer to section 3.5.
3. Operational Mode Selection
The HCT-1000 has four operational modes. The operational modes are Setup, Run,
Manual and Active Setup. The Setup mode is for modifying system or profile
parameters. The Run mode is for operating the unit with a profile that uses four
zones of heating. The Manual mode is for operating the unit with a single zone of
heat and no time limit. The Active Setup mode allows for the changing of
parameters within a running profile.
1.
Setup Mode
1.
Press the Mode button (↵) once to start "P:" flashing
2.
Use the ⊕ /  buttons to scroll through the profiles
3.
Press (↵) to select the desired profile
4.
Press and hold (↵) for 3 seconds to activate program mode (first
temperature in zone 1 will flash).
5.
Run Mode setup; proceed to step 3.1.6.1; Manual Mode setup
proceed to step 3.1.7.1.
6.
Run Mode Setup
1.
Use the ⊕ /  buttons to change the temperature to the desired
value. (Note: continually pressing either the ⊕ or  buttons for
5 seconds will change the count up/down in an accelerated
mode)
2.
When the value is set, press (↵) to move to the next parameter.
3.
Repeat steps 3.1.6.1 & 3.1.6.2 until profile is programmed.
Note: In the Cool-Down Zone you can only modify the Time
parameter
4.
Proceed to step 3.1.8.
7.
Manual Mode Setup
1.
Use the
desired value. (Note: continually pressing either the ⊕ or 
buttons for 5 seconds will change the count up/down in an
accelerated mode)
2.
Set the Time for Zone 1 to a value greater than 300 seconds.
The display will now show the word MANUAL and Z2, Z3, Z4
will no longer be shown on the display.
Note: Manual mode profiles do not have a time requirement and
once activated will run until the profile is stopped.
3.
Once required changes have been made, press and hold (↵) for
3 seconds until the LCD tops flashing, to set the profile to
memory and exit setup mode.
8.
Press (↵) to move to the next parameter. This is the HCT or MRS
option. Use ⊕ or  to switch between HCT or MRS or press (↵) to
skip
9.
Press (↵) to move to the next parameter. This is the Internal or
External TC option. Use ⊕ or  to switch between Int or Ext or press
(↵) to skip.
Note: When EXT is selected, TC1 becomes the master thermocouple
and provides feedback to the power supply.
10.
Press (↵) to move to the next parameter. This is the Airflow option
(AF). Use ⊕ to increase or  to decrease the airflow. The range is
adjustable from 1-10. Note the Air Pump will turn on will adjusting the
Airflow. Press (↵) to skip.
11.
Once required changes have been made, press and hold (↵) for 3
seconds until the LCD stops flashing, to set the profile to memory and
exit setup mode. (see Figure 1 above)
/  buttons to change the temperature to the
5