1.
To toggle between Place and Remove; press and hold the 
(blue) on the footswitch or  (blue) button on the hand-piece for 3
seconds.
4. MRS System Mode - Place
1.
Press the  (blue) on the footswitch or  (blue) button on the
hand-piece once to activate the vacuum pump and again to
deactivate.
5. MRS System Mode - Remove
1.
The integrated vacuum pick-up will automatically activate the
vacuum and retract the vacuum pick-up tube at the completion of
Zone 4 (Z4) in Run mode. The vacuum will be active for the
duration of the ZC (Cool-Down Zone).
6. MRS System Mode – Positive Vacuum Indicator
1.
VAC will be displayed when the vacuum has been activated while
in Setup or Run Mode (Figure 4). VAC will blink when a positive
seal has been achieved with the component.
7. External Thermocouple Control
1.
When using the HCT-1000 with the external thermocouple (EXT
see Figure 4 above), TC1 is used to provide external feedback
control. Ensure that the thermocouple is placed in the heat path.
Failure to do so may result in an error or damage to the
component. TC2 can be used for temperature monitoring (refer to
1.5.7)
2.
When using the HCT-1000 with external thermocouples in MRS
mode, TC1 on the HCT-1000 becomes the master thermocouple
and is used to provide external feedback for the entire system.
TC2 on the HCT-1000 and TC1 & TC2 on the PCT-1000 can be
used for temperature monitoring only (refer to 1.9 and PCT-1000
User Guide 7000-2420, section 4.4).
8. Temperature Monitoring
1.
While using the HCT-1000 with the internal thermocouple (INT
see Figure. 3 above), TC1 and TC2, the external thermocouples,
may be used to monitor temperature.
2.
Attach a thermocouple to TC1 and/or TC2 and attach to the area
to be monitored. When attached, the appropriate thermocouple
will be displayed (see Figure 4 above).
6.
Nozzle Attachment
1.
Secure the Nozzle Adapter (HNA-1) to Heater
Assembly
1.
Loosen clamp screw counterclockwise (Figure
6, 1)
2.
Close the clamp (Figure 6, 2).
3.
Slide the Nozzle Adapter up the heater
assembly (Figure 5) until it stops.
4.
Tighten the clamp screw clockwise (Figure 6,
1) for firm fit of the adapter to the heater
assembly. Once adjusted, removing the
adapter is done by opening the clamp and
sliding the adapter off the heater assembly.
2.
Nozzle to Nozzle Adapter
1.
Select the proper nozzle for the application.
1
Figure 6: Nozzle Adapter
(HNA-1)
7