Vertical Setup
The Rotary Laser can be set up to create a vertical laser
line, to check the vertical alignment of a wall or fence pole.
1. Position the Rotary Laser on its side
on a dry, flat, vibration free surface or
on a standard 5/8" tripod (not included)
or ceiling to floor leveling pole (not
included) or on any wall mount accessory
(not included). Set up the Rotary Laser
approximately level; the instrument can
compensate for a variance of up to ±5°
from the vertical plane.
2. Press the On/Off power button to turn the Rotary Laser
on. The power indicator will light up and the laser beam
will start to blink.
3. Verify that the Rotary Laser is in Automatic mode - the
manual indicator must not be lit.
4.The Rotary Laser is ready to work when the laser beam
has stopped flashing. The instrument is now level and the
laser head will rotate at 600 rpm.
5.If the laser beam is not sufficiently visible, adjust the
rotation speed (see page 13), or use the Laser Detector to
detect the laser beam (see page 15).
6.You can use the remote control to control the Rotary
Laser (see page 16). This option is very useful when
working at heights or on scaffolding.
7.To turn the Rotary Laser off, press the On/Off button.
12