3 . PRE OPERATION CHECKS

■ Make sure you have read all the warnings to prevent any risk of fire.
■ Make sure there is no flammable or hazardous material next to the pump.
■ Keep away from any naked flame. Do not smoke.
■ Install the pump at least 1 meter away from any building.
■ Never block the air flow of the pump with paper or any other material.
■ Only use the pump outdoors.

3.1. SUPPLIED ACCESSORIES

The following accessories are supplied with your pump:
2 hose connectors [(a) Fig.  0 1] composed:
- 1 lock nut;
- 1 hose connection sleeve;
- 1 sealing washer.
3 hose clamps [(b) Fig.  0 1];
1 strainer [(c) Fig.  0 1];
1 spark plug wrench [(d) Fig.  0 1];
1 instruction manual [(e) Fig.  0 1]

3.2. CHECK ENGINE OIL LEVEL

■ Never remove the oil Filling / Drain plug (dipstick plug) when the engine is running.
■ Never fill the oil sump up when the engine is running or hot.
■ Never smoke when filling the oil sump up or if, in the vicinity, there are naked flames or if any
other conditions are met to start a fire.
Make sure the pump is on a stable and flat surface:
1.
Unscrew and remove the oil Filling / Drain plug (dipstick plug) [(a) Fig.  0 2];
2.
To check the oil level, clean the dipstick plug gauge, using a clean cloth and fit the oil dipstick
back [(b) Fig.  0 2]. Do not screw it to check the oil level;
3.
If the oil level is less than the bottom level [(d) Fig.  0 2], fill the oil sump with correct oil [Fig.  0 5]
up to the top mark [(c) Fig.  0 3].
30
Oil capacity (Top level)
JARD 7 EX
0.08 L