Countertop Requirements
6" (152.4 mm)
Min. to Left
Side Wall
1/8" (3.1 mm) Min.
Clearance From
Cooktop to Start
of Radius
1-7/8" (48.4 mm) Min. to
Counter Front
Gas Requirements -
Supply Pressure
Propane Gas Installation
English 4
Figure 2 - Cutout Dimensions
1-7/8" (48.4 mm) Min. to
Combustible Wall
A
7-1/8" (181.3 mm) Min.
to Left Side Wall
Table 1: Cooktop Models
# Cooktop
A
Cutout
B
Cutout
C
Corner
D
Overall
•
Natural Gas - 6 inches water column (14.9 Millibars) minimum.
•
Propane Gas -11 inches water column (27.4 Millibars) minimum.
The propane gas tank must be equipped with its own high pressure regulator in
addition to the pressure regulator supplied with this unit. The cooktop is shipped
from the factory for use with natural gas. For use with LP conversion kit – Model
SNLPKIT4/5/6, must be purchased separately. A qualified technician or installer
must do the conversion.
3" (76.2 mm) Min.
to Right Side
Wall
21" (533.4 mm) cooktop depth
B
C
D
30" Models
36" Models
19-1/8" to 19-7/8"
19-1/8 to 19-7/8"
(486.1 to 505.6 mm)
(486.1 to 505.6 mm)
28-15/16" to 29-3/8"
34-15/16" to 35-3/8"
(735.2 to 746.6 mm)
(887.6 to 899 mm)
30" (762 mm)
36" (914.4 mm)
31" (787.4 mm)
37" (939.8 mm)
4" (101.6 mm) Below Countertop
4-1/8" (105.1 mm) Min.
to Right Side Wall
45" Models
19-1/8 to 19-7/8"
(486.1 to 505.6 mm)
43-15/16" to 44-1/2"
(1116.2 to 1130.6
mm)
45" (1143 mm)
46" (1168.4 mm)