The Machine Stops - Radio Control; The Fuse Trips Frequently; The Machine Cannot Cope - Husqvarna HTC 950 RX Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
6.6

The machine stops - radio control

Other equipment can interfere with the radio traffic between the machine and the radio
control unit, which means that the communication error indicator (ComError) can start
to blink on and off. When the contact between the machine and the radio control has
been broken for too long the machine stops for safety reasons.
Check if the communication error indicator (ComError) blinks.
Restart the machine and switch off any interfering equipment.
Check the error code in the display on the frequency converter, see Electronic
error codes, page 39.
6.7

The fuse trips frequently

The load is too high on the distribution box to which the machine is connected.
Change socket, see .
Check the tools. Ensure that the correct tools are used, that they are in working
order and that they are correctly fitted.
6.8

The machine cannot cope

Reduce the grinding pressure.
Heavy load. Press the handle down slightly so that the grinding head eases
slightly away from the surface being ground..
Run half of the machine on the surface to be cleaned and half on the clean
surface. This removes any residue from the tools.
Check the tools. Ensure that the correct tools are used, that they are in working
order and that they are correctly fitted.
Voltage drop. Check the cable area and the cable length comply with HTC's
recommendations.
38
HTC 950 RX
5.0

Publicidad

Tabla de contenido
loading