Descargar Imprimir esta página

Daikin SRC-COA Manual De Instrucciones página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
1.
TEMPERATURE (Seven Segments)
To indicate the ambient temperature set by the user.
2.
MODE
To indicate the selected operating mode: HEAT & DRY / COOL / FAN
(LED green / yellow / red).
3.
VENTILATION SPEED
To indicate the selected ventilation speed: LOW / MED / HIGH
For U1-SB125 only have single speed: HIGH.
4.
AUTO SELECTION
Automatic selection for speed, whereby the speed is automatically adjusted according to the room temperature.
5.
FAN AND VENTILATION MODE
Press the fan button to set the desired selection.
6.
OPERATION SELECTION MODE
Press the mode button to select the type of operation mode.
Cooling unit: COOL, DRY, FAN.
Heat pump unit: AUTO, COOL, DRY, FAN, HEAT.
The Auto mode is unavailable for Chilled Water (CW) 2 pipe system.
It is available for Chilled Water (CW) 4 pipe system.
7.
TEMPERATURE SETTING
Set the desired temperature.
Press ▲ or ▼ button to increase or decrease the set temperature. The setting range is between 16°C to 30°C (60°F to
80°F).
8.
TIMER SWITCH SETTING
Press the set button to activate the switch timer of the air conditioner unit (the setting range is between 1 to 10 hours).
The unit will be at ON or OFF state in function of operating mode.
9.
"SLEEP " FUNCTION
Press the sleep button to select the sleep function. This function cannot be selected if the air conditioner unit is
operating under FAN mode only or dry mode. For SLEEP function operating under COOL mode, the set temperature
increases by 0.5°C after 30 minutes, another 0.5°C after the next 30 minutes and 1°C after the following 1 hour.
When the unit is operating under heating mode, the set temperature decreases by 1°C after 30 minutes, another 1°C
after the next 30 minutes and 1°C after the following 1 hour.
10.
"ON/OFF" SWITCH
Press once, the air conditioner unit starts.
Press again, the air conditioner unit stops.
11.
IR RECEIVER
12.
AUTOMATIC AIR SWING (OPTIONAL)
Press the SWING button to activate the automatic air swing function.
To distribute the air to a specific direction, press the button and wait until the louver move to the desired direction
and press the SWING button once again.
Room Sensor missing/Short
Indoor coil sensor missing/Short
Outdoor coil sensor missing/Short
Compressor overload
Outdoor abnormal compressor
overload trip or gas leak
Pump fault
NOTE:
Function 3, 4, 5, 12 are not applicable for Roof Top models.
Function 6 (Dry Mode) is not applicable for Roof Top models.
Function 12 (Automatic Air Swing) mode is not applicable for ducted models.
OM-SLM-1206(1)-Daikin
OPERATING INSTRUCTION
Error
1
1
Seven Segments
E1 blinking
E2 blinking
E3 blinking
E4 blinking
E5 blinking
E6 blinking
2/12/09, 4:40 PM

Publicidad

loading

Este manual también es adecuado para:

Src-hpa