Dat.
A
1 2 3 4 5 6 7
Dat.
Dat.
24
22
2
20
4
18
6
16
8
14
10
12
C
Service
B
K
1-7
N
C
1 2 3 4 5 6 7
D
Dat.
Dat.
24
22
2
20
4
18
6
16
8
14
10
F
12
E
Service
K
1-7
N
3
18
HOLIDAY PROGRAM CHANGE/SETTING
-3
+3
PC-Sercvice
4
-3
+3
PC-Sercvice
1
2
To access the holiday program setting function, press (
placed next to the icon shown in the figure; when this key is pressed,
the (A) signal symbol will be displayed to the right of the function
printed on the left side of the regulation (page 5 MANAGEABLE
OPERATIONS table) after this, remember that each time the key is
pressed, the cursor will move to the next function. To exit the function
selection mode, scroll the cursor up to the last function (service) and
press the navigation key again. The (C) symbol identifies the circuit
that is being changed or set; to go from one circuit to the other,
press the corresponding key (
module can operate two circuits at most; but in the case that only
one circuit has been included, it will not be possible to select circuit
2.
Once the circuit is selected, the time switch program for holidays
will be displayed; the regulation operates a maximum of 6 intervals
(departures/returns). The setting procedure is the following:
The (E) index indicates if the date represents a departure or a return
(1,3,5,7,9, 1 1 are the departures; 2,4,6,8, 1 0, 1 2 the returns); press
(
) and (
) to increase or decrease the (F) date corresponding
to the departure or return; once the correct date for the departure
is selected, press (
) to go to the corresponding return, which is
N
set using (
) and (
); if it is not necessary to set all the intervals,
press (
) to go to the next function and save the setting. To delete
a set interval, select the interval to be deleted using (
down the (
) key until the date is deleted; and to delete all the inter-
vals, hold down the (
) key for more than 5 seconds. During the
holiday program operation, the unit will function as follows:
• In case the (D) selector is set in "normal/reduced" mode (
the unit will function in reduced mode until the day set as return,
after which it will return to the normal mode;
• In case that the (D) selector is set in "frost/reduced" (
during the set holiday period, the mode will be reduced. Remember
that the boiler charge is off in the programmed zones according to
the holiday time.
) until it is
); remember that the standard
K
) and hold
N
),
),

Hide quick links: