4. Test pump operation by filling the sump with water
while the main pump is unplugged. If the pump
operates properly, plug the transformer into the GFCI
protected outlet to begin charging the battery.
5. Protect electrical cord from sharp objects, hot surfaces,
oil and chemicals. Avoid kinking the cord and replace
damaged components immediately.
Operation
Always disconnect the power
source before attempting
to install, service, relocate or maintain the pump.
NEVER touch sump pump motor, water or discharge
piping when pump is connected to electrical power.
NEVER handle a pump or pump motor with wet hands or when
standing on wet or damp surface or in water. Fatal electric
shock COULD occur.
Risk of electrical shock! Usea
GFCI receptacle to reduce the
risk of fatal electric shock. Cutting the cord WILL
void the warranty and make the pump inoperable.
1. After installation, the back-up pump will start
when the water level rises above the depth that
the primary pump should start.
2. The control box has a DC charger designed to
shorten the recharging time of your battery, and to
prevent overcharging. In addition, the control box has
a time delay which keeps the pump from repeated,
short cycles when it shuts off. The time delay feature
will allow the pump to run 20-25 seconds after the
switch reaches the off position.
3. The control box contains multi-colored indicator
lights. When AC power is present, the lights will
indicate the charging state, and not reflect actual
battery voltage, particularly with a defective battery. In
order for the indicator light to provide an accurate
reading, steps "a" through "d" must be followed.
Unplug main AC pump and the
transformer. Risk of electrical shock!
a. After main pump and transformer are unplugged, a
power off alert tone will sound for 30 seconds.
b. Lift and release the fl oat switch to activate the back
up pump.
c. When the pump stops, read the charge indicator lights:
Green: Indicates the battery is fully charged.
Yellow: Indicates battery is partially charged, but still
operable.
Red: Battery is completely discharged or defective.
Red blinking: Battery discharged below level where
pumping can occur. Motor is locked out by controller
until battery is sufficiently charged to run pump.
d. Plug in transformer and main AC pump.
When main AC power is out, and when pump has been
running, the lights will indicate battery status.
4. A chirping sound from the control box will accompany
the red light, indicating that the battery may require
attention or replacement. Voltage is only an indicator
of battery condition and may not reflect the true
condition of the battery. See maintenance for
instruction on assessing battery condition.
5. A single thirty (30) second tone will sound when
power to the system is interrupted and the power
failure light will illuminate. The unit will reset and the
light will go out automatically when power is restored.
6. A three (3) second tone will sound every time the pump
starts.
Maintenance
Always disconnect the
electrical supply before
attempting to install, service or relocate or perform
any maintenance. If the power source is out of sight,
lock and tag in the open (off) position to prevent
unexpected power application. Failure to do so COULD result in
fatal electric shock. Only qualifi ed electricians should repair this
unit. Improper repair COULD result in fatal electric shock.
Once a month, check the battery
condition. To check battery condition
follow steps listed below:
1. Unplug the transformer.
2. For batteries with top caps that can be removed, the
electrolyte level should be checked and filled tomanufacturer's
specifications. The charge for each cell
should be checked with a hydrometer. A gravity of 1.265
indicates the battery is at full charge. If the
specific gravity of any of the cells varies more than
.050, the battery should be replaced.
NOTE: An inexpensive hydrometer can be purchased at an
automotive parts dealer.
3. Inspect the terminals and clamps for corrosion and
tightness. Clean and tighten as required.
4. Unplug the main pump and fill sump with water until
back-up pump turns on. Repeat process two times to
make sure pump is operating normally.
5. If pump operates normally, plug transformer into
wall outlet, turn on main pump. If pump fails to
operate normally, see Troubleshooting guide and
correct problem. Repeat step 5.
5