Saddle Connection
Ø 1/4"
(32 mm)
Foam Seal
Black Tube
3. Connect to the Drain
CAUTION: Risk of Property Damage. Do not drill through the opposite side of the drain tailpiece.
NOTICE: Do not connect the drain line downstream of a disposer or in a horizontal pipe.
NOTE: If the system is being installed in a region governed by the UPC, a UPC-approved drain line
adapter should be used. Follow the "Drain Line Adapter" instructions.
Saddle Connection
Punch out the center hole on the foam seal and use as a template to locate the drilling position
above the drain tap.
Mark the location with a pencil.
At the marked location, drill a 1/4" (32 mm) hole through the wall of the drain pipe.
Remove the film from the foam seal and attach to the inside of the front plate of the drain saddle,
aligning the holes.
Position the saddle on the drain tailpiece and securely tighten using the nuts and the screws
provided.
Route the 3/8" black tube from the faucet air gap to the connector on the saddle.
Cut the black tube as needed for a taut path to the connector. Do not kink the hose.
Insert the end of the black tube into the connector approximately 1" (25 mm) until it stops.
Drain Line Adapter
Install the drain line adapter (not provided) to the drain tailpiece with the connector facing up.
Route the 3/8" black tube from the faucet air gap to the connector on the adapter. The tube should
not drop below 45° from a vertical position.
Cut the black tube as needed for a taut path to the connector. Do not kink the hose.
Insert the end of the black tube into the adapter until firmly seated in the connector.
1395432-2-B
Drain
Saddle
Drain Line Adapter
Black
Tube
45˚
6
Drain Line
Adapter