STEP 7: FINE-TUNE TANK WATER LEVEL
A: FLUSH THE TOILET
TO CHECK THE TANK
WATER LEVEL
After the water stops filling the
tank, the water level should be
roughly ½ inch below the top
of overflow pipe to ensure a
proper flush.
B: WATER LEVEL IS TOO LOW
Turn the tank water level adjustment screw clockwise
to raise the float. Flush to reset water level.
WATER LEVEL IS TOO HIGH
Turn the water level adjustment screw counterclock-
wise to lower the float. Flush to reset water level.
10
1/2"
Overflow
Pipe
See Step 6C for Full Tank view
Bowl Water Level
Setting for Most Toilets
Tank Water Level
Adjustment Screw
+
STEP 8: FINE-TUNE BOWL WATER LEVEL
NOTE: The PerforMAX Fill Valve is pre-set to fill the proper bowl water
level in most toilets straight out of the box (see previous page).
A:
FILL BOWL WITH A GALLON
OF WATER
Wait 1 minute until the bowl water level
recedes down and stops.
B:
MARK THE WATER LEVEL IN
THE BOWL
With a pencil, draw a line at the top of
the water level in bowl. (Pencil mark will
easily wash off).
C:
FLUSH TOILET TO CHECK BOWL
WATER LEVEL
If the water level matches the line you've
made in the bowl when the fill valve stops
filling the tank, the water level is correct,
proceed to Step 9.
If the water level matches the line in the
bowl and the fill valve is STILL FILLING,
then the bowl water is TOO HIGH, proceed
to Step 8D.
If the valve shuts off and the water level does
NOT match the line in the bowl, the water
level is TOO LOW, proceed to Step 8D.
D:
ADJUST THE BOWL WATER LEVEL
TOO HIGH:
Turn the dial clockwise.
TOO LOW:
Turn the dial counter-clockwise.
TOO HIGH
TOO LOW
LESS WATER
MORE WATER