Installation instructions
Checking the flame quality:
All combustion flames need to be visually checked to determine their flame
quality.
1
2
3
22 English
Install_NX60A6_DG68-01337A-00_EN+MES+CFR.indb 22
Install_NX60A6_DG68-01337A-00_EN+MES+CFR.indb 22
1. Soft blue flames—Normal for natural gas
operation.
2. Yellow tips on outer cones—Normal for LP
gas operation.
3. Yellow flames—Abnormal for any gas
operation; call for service.
NOTE
If burner flame looks like 3, the range
should not be used until it is serviced. Call
for service. Normal burner flames shall look
like 1 or 2, depending on the gas type you
use.
Step 9. Final installation checklist
You have just completed installing your range. Make sure all controls are in the off
position and the flow of ventilation air to the range is unobstructed. The following
is a checklist to confirm your range is safely installed and ready for operation.
– Gas line has been properly connected to
– Range is plugged into the properly
– Approved anti-tip bracket is properly
Gas Range Plug
– Range is leveled and is firmly sitting on a
– Gas surface burners have been properly
– All burners have been tested for proper
– FOR INSTALLER ONLY—Check and/or
Locking screw
Adjusting the oven burner air adjustment shutters
All oven burners have an air adjustment
shutter. The purpose of the shutter is to
Air
regulate the flow of air to the flames.
adjustment
Properly adjusted flames should burn
shutter
steadily with approximately 1-in of blue
cone. The flames should never extend
past the edge of the burner baffles. Even
though these are preset at the factory, they
should be checked and, if needed, adjusted
periodically to ensure efficient operation.
the range. The gas has been turned on. All
connections have been checked for leaks.
grounded electrical receptacle.
installed and engaged with the range.
solid, level floor.
assembled.
operation.
adjust the broil and oven burner flames as
described on pages 21-22 in this manual.
2020-12-30
2020-12-30
10:56:14
10:56:14