Authorization Via Key Switch - Eaton xChargeIn Instrucciones De Manejo

Ocultar thumbs Ver también para xChargeIn:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 122
xChargeIn
5.2.4
Deleting RFID cards
In some cases, it is necessary to delete the taught-in RFID cards. For exam-
ple, after loss of an RFID card or in oder to charge without authorization. It is
only possible to delete all taught-in RFID cards; deleting a single RFID card
is not possible.
To do this, proceed as follows:
1) Remove the housing cover and connection panel cover to access the
2) Hold the service button pressed in the connection panel until the second
If the deletion was successful, the LED bar flashes green and charging with-
out authorization is possible.
5.2.5
RFID authorization at charging network
If the charging station: is part of a charging network (xChargeIn S Series as
slave charging station: in a master/slave network), then all RFID cards must
be taught in on the master charging station (xChargeIn M Series). The ad-
ministration of the permitted RFID cards for the entire charging network is
carried out at the master charging station. Information on this can be found
in the specific "Configuration Manual".
5.3

Authorization via key switch

If the charging station is equipped with a key switch, a charging process can
only be started by means of a key. The key is only necessary for starting the
charging process; after this the key can be removed, since the charging
process is continued even without the key attached.
Operating instructions V1.04
© EATON
service button (see
5.2.1 Preparing the charging
signal tone sounds (approx. 10 seconds).
The charging station will now automatically perform a restart, deleting all
previously taught-in cards in the process.
Authorization
station).
117

Publicidad

Tabla de contenido
loading

Tabla de contenido