13
Operation mode (page 2&3)
The dimmer module will operate as follows, according to the configuration of the hexadecimal rotating switch:
Start/stop timer : Operating the push button will turn the lamp on. After the set time has elapsed, the lamp will be turned off.
0 or 8*
Operating the push button while the lamp is on will switch off the lamp immediately.
Staircase lighting timer : Operating the push button will turn the lamp on. After the set time has elapsed, the lamp will gradu-
ally turn off and will be completely switched off after 30 seconds.
1 or 9*
Operating the push button while the lamp is on will restart the timer.
Dimmer :
A short press will turn on the lamp to full intensity.
A short press while the lamp is on will switch off the lamp.
2 or A*
A long press will dim the lamp until the maximum or the minimum is reached. A next operation will reverse the dimming
direction.
After the set time has elapsed, the lamp will turn off.
Dimmer with memory function :
A short press will turn on the lamp at the intensity which was last used.
A short press while the lamp is on will switch off the lamp.
3 or B*
A long press will dim the lamp until the maximum or the minimum is reached. A next operation will reverse the dimming
direction.
After the set time has elapsed, the lamp will turn off.
Multi-position dimmer : Operating the push button will turn on the lamp to full intensity. Each time the push button is pressed
within 5 seconds after the previous operation the light intensity will modify with 25%. If the lamp is on and the previous operation
4 or C*
happened more than 5 seconds ago, the lamp will turn off.
After the set time has elapsed, the lamp will turn off.
8