The pumps are shipped with a threaded vacuum breaker installed.
Fill-Rite recommends that the vacuum breaker be tubed back to the
tank. The vacuum breaker is used to break a siphon should an open
nozzle or a leaking hose be below the fluid level in the tank with the
pump turned off.
The following illustration shows methods of installing tubing for the
vacuum breaker that terminates in the vapor space at the top of the
tank. The tubing must terminate in the vapor space; if the tubing
terminates below the liquid level of the tank, the vacuum breaker will
not prevent siphoning. It is also very important that there are no
liquid traps in the tubing. The tubing must have a continuous slope
from the pump down to the tank. If the pump is installed below the
top of the tank, the tubing may slope both ways from a single high
point above the tank. Alternately, tubing can be piped to any
available opening on top of tank it the tank adapter is not used. Use
reducer bushings as required.
Tuthill Transfer Systems ("Manufacturer") warrants to each
consumer buyer of its Fill-Rite products (the "Buyer"), from the date
of invoice or sales receipt, that goods of its manufacture ("Goods")
will be free from defects of material and workmanship. Duration of
this warranty is as follows:
• Heavy Duty Products - Two years
• Standard Duty Products – One year
• Economy Duty Products – One year
• Cabinet pumps, Parts, and Accessories - One year
Manufacturer's sole obligation under the foregoing warranties will
be limited to either, at Manufacturers' option, replacing or repairing
defective Goods (subject to limitations hereinafter provided) or
refunding the purchase price for such Goods theretofore paid by
the Buyer, and Buyer's exclusive remedy for breach of any such
warranties will be enforcement of such obligations of Manufacturer.
If Manufacturer so requests the return of the Goods, the Goods will
be redelivered to Manufacturer in accordance with Manufacturer's
instructions F.O.B. Factory. The remedies contained herein shall
www.tuthill.com
VACUUM BREAKER
VACUUM BREAKER TUBING INSTALLATION
ANTI-SIPHON LINE
(NOT INCLUDED)
PRODUCT WARRANTY
8825 Aviation Drive
Fort Wayne, Indiana USA 46809
Tel 260 747-7524 Fax 260 747-3159
Fill-Rite recommends using the vacuum breaker tank adapter with a 1/4
npt opening in the side of the hex portion that terminates in the vapor
space of the tank. Install tank adapter per instructions found in this
manual. Make liquid tight connection from the adapter to the vacuum
breaker using a minimum of 1/4 metal tubing compatible with the liquid
being pumped. If a vacuum breaker tank adapter is used and the 1/4 npt
opening is not used for the tubing, plug the opening liquid tight.
PUMP
700F0651 ADAPTER
SKID TANK
constitute the sole recourse of the Buyer against Manufacturer for
breach of warranty. IN NO EVENT SHALL MANUFACTURER'S
LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF THE
MANUFACTURE, SALE, DELIVERY, OR USE OF THE GOODS EXCEED
THE PURCHASE PRICE OF THE GOODS. The foregoing warranties
will not extend to Goods subjected to misuse, neglect, accident or
improper installation or maintenance, or which have been altered or
repaired by anyone other than Manufacturer or its authorized
representative. THE FOREGOING WARRANTIES ARE EXCLUSIVE
AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY,
FITNESS FOR PURPOSE OF ANY OTHER TYPE, WHETHER EXPRESS
OR IMPLIED. No person may vary the foregoing warranties and
remedies except in writing signed by a duly authorized officer of
Manufacturer. Warranties or remedies that differ from the foregoing
shall not otherwise be binding on Manufacturer. The Buyer's
acceptance of delivery of the Goods constitutes acceptance of the
foregoing warranties and remedies, and all conditions and limitations
thereof.