COLUMBIA VAC OPC 120 Manual Del Usuario página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
wakes up the display. The device switches on when the air humidity is 3% higher than the
set value. First the fan starts operating and after about 3 seconds the compressor switches
on.
When the air humidity is less than the set value by 3%, the compressor switches off and the
fan continues to run for about 30 seconds.
A 3-minute delay of the compressor is programmed in the device, which means that
despite the increase in humidity, the dryer will not always switch on immediately.
In night mode, the beeper is switched off.
Only the humidity setting can be adjusted.
HUM
- humidity level setting
Manual setting of the humidity level is possible when the „AUTOMATIC" or „NIGHT"
program is active. When the „CONTINUOUS DEHUMIDIFICATION" program is activated,
the humidity level cannot be changed.
To set the humidity level, select „AUTOMATIC" or „NIGHT" and then press the key
the display shows the desired value in the 30-80% range.
Temperature
The appliance has a built-in thermometer. To view the room temperature on the display,
press and hold the "HUM SET" button
Display
-
when the appliance is on, it shows ambient humidity,
-
when setting the humidity level, it shows the value from the range "30-80",
-
when setting the "TIMER" function, it shows values from the range "00-24",
-
after pressing and holding the button for about 3 s, it shows ambient temperature.
"SPEED" button
A single press of the "SPEED" sets the fan speed, which is indicated by the indicator lights:
- high,
- low.
You cannot select the fan speed when the continuous and night programs are activated
and when the buttons are locked.
"LOCK" button
- button lock
To activate the button lock, press and hold the "LOCK" button
Function activation is indicated by the indicator light.
26
for about 3 s.
- fan speed selection
until
for a few seconds.

Publicidad

Tabla de contenido
loading

Productos relacionados para COLUMBIA VAC OPC 120