7
TRoUBLES aND REMEDIES
Disconnect nailer from hose before servicing. When connecting the tool, it must contain no fasteners.
TRoUBLE
air leaking from exhaust
port.
air leaking from release
valve (77a) (light blowing
permissible)
Blow does not take place.
Idle impact or nails are not
fully driven in.
Nailer operates too slowly.
Set of wear-and-tear parts
During repair replacement of parts the special grease (code no. 68 3868) must be applied to the surface of
the cylinder and the counter surfaces of the O-rings.
PoSSIBLE CaUSE
o-rings (9 u. 11) damaged or dirty.
Release valve damaged.
Nailstrip jammed.
Control parts move with difficulty
after long term storage.
Tool is applied too weakly for too a
short time.
Tool exhausts considerably in the
lowest position of the piston, o-ring
(15), bumper (6, 7), Cylinder ring
(0) worn or damaged. No backstroke.
Nosepiece (9) defective.
Tool without sufficient lubrication.
air pressure too low.
Tool jumps.
Connection hose too long. Diameter
reduced in the air line or in the
maintenance unit (fall of pressure).
Piston completely (17a) damaged.
Tip of driver worn.
Penetration setting wrongly adjusted.
Safety yoke (a) sluggish.
Control parts frozen-up.
Release valve (77a) damaged.
Code No. 73 740
REMEDY
Clean or replace parts.
Have tool checked by service
workshop.
Remove the obstruction.
Increase air pressure and make some
trial blows. Then reduce air pressure
immediatel .
apply tool more firmly
Replace damaged parts.
Have tool checked at service station.
Clean the interior pieces, grease the
counter surfaces of the o-rings and
the surface of the cylinder. Check the
lubricator.
adjust to correct air pressure (min. 5
bar / 0,5 MPa).
Press tool more firmly onto the
workpiece.
Investigate and correct trouble.
Replace piston. at the same time
check bumper (6, 7) for wear.
Grind face of driver tip.
Set correctly according (see 5)
Eliminate the jamming cause.
Check operation of water separator.
Have tool checked by service
workshop.
5