Place it in the installation point previously
chosen, and mark the points on the wall
where the holes are to be drilled.
Insert the screw anchors supplied into
the holes made. (fig. 15A).
Place the control unit on the wall,
matching the brackets holes with the
plastic anchors and then fasten with the
screws supplied (fig.15B).
Ducts connection: the appliance is
equipped with an inlet and outlet for
ducts connection (check the air direction
shown in the external label before instal-
ling the exhaust ducts, fig. 16), connect
the ducts and secure them using suitable
metal clamps (ducts and clamps shall be
provided by the installer ) . The duct in
fig. 16A must be connected to D7960B,
the duct in fig. 16B is to be directed to-
wards the outside of the building or insi-
de your house if your hood works in the
filtering mode.
Connect the external motor cable to
the terminal block found inside the
plastic box in the hood . Make sure
to follow the wires colours when
performing the electrical connection
(fig.17).
DHK8000
DHK8000 has been designed to be in-
stalled under the kitchen cabinet , whe-
re the lower air outlet of DHD7960B is
found.
Installation is possible on cabinets
whose height ranges from 900mm and
960mm. The appliance has been desig-
ned to extract vapours abd odours in an
optimal yet extremely silent way.
Installation procedure: Place the ap-
pliance under the Downdraft where the
air outlet is found, as shown in (fig. 18).
All unions are supplied with the applian-
ce, along with a rectangular pipe to con-
nect the downdraft to DHK8000.
The rectangular pipe connecting the two
appliances can be cut according to the
cabinet height , see fig. 18. The pipe
current length allows for installation in
960mm height cabinets.
Please take the overall dimensions
shown in figure 19 into account .
Drilling on the cabinet bottom shall vary
according to the distance of the cabinet
from the floor.
If the cabinet bottom is higher than
120mm, you just need to drill the hole to
let the pipe in , see fig. 21. The hole di-
mensions are 240x100mm in this case.
If the cabinet bottom height is lower than
120mm from the floor , then you will need
to make an opening that can house the
appliance DHK800, as shown in fig. 22:
in such a case the opening dimensions
will be as follows: 410mm x 410mm.
In this second case , the use of the metal
fixing bracket supplied with the applian-
ce DHK800 can be useful, as shown in
figure 23.
The appliance air outlet shall be con-
nected to the cabinet outlet, so that air
collected into the kitchen can be re-cir-
culated into the room in case of filtering
version. If your appliance works in suc-
tioning mode, then the ducting shall re-
ach the outside of the building.
Ducts to be connected to the DHK8000
air outlet are not supplied with the ap-
pliance.
You can direct the appliance air outlet
according to your installation needs, by
simply rotating the air outlet flange, as
shown in figure 20.
The appliance is equipped with a 1.5
meter long power cord to be connected
to the downdraft specific terminal block
found inside the black plastic box, (Fig.
17).
Caution: do not drill any other hole on
the appliance , in order prevent any
damage on the sliding internal com-
ponents and on the electric ones, as
well .
8) Connect the appliance to the power
supply.
9) Start to open the extractable unit (see
' How the hood works' chapter ) and re-
move all the protections(fig. 6-7). Then
open the small door (fig. 8) and remove
all the protections.
Remove the PVC protection from the
grease filters and place them as shown
in fig. 9.
37