Cod. 99877 – DURANIUS
Check that the filter is fitted in the
water inlet pipe and that it is not
clogged up.
5. Connect the water hose to the water
supply
by
connector
pressure: 10 bar, max. temperature:
40°C).
6. Turn on the water.
3.5 Start/stop of the machine
The trigger gun and lance is affected by
a thrust during operation - therefore
always hold it firmly with both hands.
IMPORTANT: Point the nozzle at the
ground.
7. Check that the machine is in upright
position. NOTE: Do not place the
machine in high grass!
8. Release the trigger lock.
9. Activate the trigger of the trigger gun
and let the water run until all air has
escaped from the water hose.
10. Press the Start/stop switch.
11. Activate the trigger of the trigger
gun.
12. Always adjust the distance and thus
the pressure of the nozzle to the
surface, which is to be cleaned.
Do
not
cover
operation or use it in a room without
adequate ventilation!
means
of
the
(inlet
water,
the
machine
NOTE: If the machine is left or not used
for 5 minutes, it must be switched off on
the start/stop switch "O":
5. Press the start/stop switch "O".
quick
6. Disconnect the electrical plug from
max.
the socket.
7. Shut
activate the trigger of the trigger gun
to relieve the machine of pressure.
8. Lock the trigger gun .
When releasing the trigger of the trigger
gun, the machine automatically stops.
The machine will start again when you
re- activate the trigger gun.
3.6 Multi Nozzle
The pressure can for the multi nozzle
be adjusted by tuning it. WARNING: Do
not do this under operation to avoid that
the hand hits the jet.
during
off
the
water
supply
and
26