Technical Data; Maintenance / Care - Würth 0715 53 07 Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15

Technical data

Item
Nominal voltage
Indicator
Degree of protection
Test current
Dimensions
Weight
TÜV/GS
Operation
Note
Ensure that you hold only the handle;
never come in contact with the crocodile
clip [5] and the test probe [2] during a
test.
Voltage test
Connect the crocodile clip [5] to ground (bare
metal of the car).
Touch a fuse or the positive terminal of the battery
with the test probe [2].
3 The LED (+) illuminates if connected to a live wire.
Battery test
Connect the crocodile clip [5] to the negative
terminal of the battery.
Touch the positive terminal with the test probe of
the device [2].
3 The LED (+) illuminates if connected to a live wire.
Testing the brake / rear light
Connect the crocodile clip [5] to ground (bare
metal of the car).
Touch the bulb socket with the test probe [2] to
test it.
Testing the line
Connect the crocodile clip [5] to ground.
Slide the piercing unit [3] back using the slider
[4], which is attached to the side, fasten the
line and pierce it with the piercing contact point.
3 The LED (+) illuminates if connected to a live wire.
0715 53 07
6 - 48 V DC
4 LEDs
IP 40
approx. 15 mA/48 V
145 x 25 x 16 mm
approx. 120 g
IEC/EN 61010-1
DIN VDE 0680, part 5
Polarity test
Connect the line to be tested to the crocodile
clip [5].
Touch the positive terminal of the battery with the
test probe [2].
3 If the wire is connected to ground, the LED (+)
illuminates.
3 If the wire is supplied with battery voltage, the
LED does not illuminate.
Repeat this test and touch the negative terminal
of the battery with the test probe [2].
3 If the wire is live, the LED (-) illuminates.
3 If the wire is connected to ground, the LED does
not illuminate.
Important!
Do not apply a voltage that exceeds
60 V DC to the test probes [2]. If you
exceed this limit, the device can be
damaged and the operator placed at
risk.
Warning!
The device must not be used for
measurements of the mains supply. The
device must not be used for measure-
ments of voltages exceeding the values
stated in these operating instructions.
Warning!
The device must not be used for meas-
urements of other categories such as
CAT II, CAT III or CAT IV.

Maintenance / Care

If the device has become dirty due to daily use,
the device can be cleaned with a damp cloth.
Never use aggressive cleaning agents or solvents
for cleaning.
7

Publicidad

Tabla de contenido
loading

Tabla de contenido