KEY DiMENSiONS
AND SPECiFiCATiONS
Description
Dryer (Gas and Electric)
Electrical Requirements
Refer to the rating labet
Gas Requirements _ NG:
4-10.5
inches WC (Water Column)
Gas Requirements _ LP:
8-13 inches WC
Dimensions
27 in. (W) X 30 1/4in. (D) X 38 in. (H), 52 1/4 in. (D with door open)
68.6 cm (W) X 76.7 cm (D) X 96.5 cm (H), 132.7 cm (D with door open)
Net Weight
Electric : 147 lb. (66.7 kg) Gas : 150.5 lb. (68.3 kg)
Drying Capacity
IEC 7.3 cu. ft.
_Gas Models Only
LOCATION
REQUIREMENTS
Standard
Installation
- Side View
iMPORTANT:
Read att installation
instructions
completely
before
installing and operating
your dryer,
i
It is important
that you review this entire manual before
2o 1/8in.
installing and using your dryer. It contains detailed
(56.2 cm)
instructions concerning
electrical
connections,
gas
connections
and exhaust requirements.
CHOOSE
THE PROPER LOCATION
* Store and install the dryer where it witl not be exposed
to temperatures
below freezing
or exposed to outdoor
weather
conditions.
* Choose a location
with a solid, level floor.
*If the dryer is being installed in a garage,
place the
dryer at least 18 inches (45.7cm)
above the floor.
* Properly ground the dryer to conform
with all
governing
codes and ordinances.
* To reduce the risk of electric
shock, do not install the
dryer in damp or wet locations.
iMPORTANT:
If you are installing
your
dryer
in a
manufactured
or mobile
home,
please
refer
to the
Special
Electrical
Requirements
for Mobile
or
Manufactured
Homes
section.
CLEARANCES
* Most installations
require a minimum 5 1/2 inch (14 cm)
clearance
behind the dryer for the exhaust ducting.
* Allow minimum
clearances
of at least 1 inch (2.5 cm)
on the sides and back to minimize vibration
and noise.
* Allowing
additional
clearance
for installation
and
servicing
is recommended.
Be sure to allow for wall, door, or floor moldings that
may increase the required
clearances.
* Allow at least 21 inches (53.3 cm) in front of the dryer
to open the door.
Standard
Installation
- Front View
oJo
in.
cm)
l in.
l in.
(2.5 cm)
27 in.
(2.5 cm)
(68.6 cm)
m
J
3"
(7.6 cm)
_
Vent
48 sq. in. --
(310 sq. cm.)
Vent
24 sq. in.
(155 sq. cm.)
y
-
3"
_
(7.6 cm)
0
Additional
instructions
for closet installations:
The closet door must allow for sufficient airflow. Refer to the
diagram
above for minimum vent opening requirements. A
louvered door is also acceptable.